LSI SAS2 manual Expanding an Integrated Mirroring Volume with OCE

Page 16

Chapter 3: Creating Mirrored Volumes Creating Mirrored Volumes

SAS2 Integrated RAID Solution User Guide

3.2.3Expanding an Integrated Mirroring Volume with OCE

4.Move the cursor to the RAID Disk column and select a line that has a No entry in this column, which indicates that the disk is not already part of the volume you are creating. To add the disk to the new array, change the No to Yes by pressing the space bar.

CAUTION: The SAS2 BIOS CU deletes all existing data from the disks drives when you select them to use for a mirrored volume.

5.Move the cursor to another line and press the space bar to add another disk to the array.

If you select an odd number of disks, the SAS2 BIOS CU creates an Integrated Mirroring Enhanced array. If you select an even number of disks, it creates an Integrated Mirroring + Striping array. As you add disks, the Array Size field changes to reflect the size of the new array.

6.Press C to create the array. A menu window appears.

7.From the menu options, select Save changes then exit this menu.

A processing message appears briefly, and then the SAS2 BIOS CU returns to the Adapter Properties window. Initialization of the new array continues in the background.

NOTE: To create a second Integrated Mirroring Enhanced or Integrated Mirroring + Striping volume, repeat the instructions above.

NOTE: See the instructions in Section 3.3, Managing Hot Spare Disks, if you want to create one or two global hot spares.

You can use the online capacity expansion (OCE) feature to expand the capacity of a two-disk Integrated Mirroring (RAID 1) volume by replacing the original disks with two higher-capacity disk drives while the volume remains online. This process maintains data integrity at all times, even if one of the disks fails during the replacement process. The new disks must have at least 50 GB more capacity than the disks they are replacing, and they must use the same protocol (SAS or SATA) as the disks they are replacing.

Follow these steps to expand an existing RAID1 volume with OCE:

1.Physically replace one of the two volume disk drives with a drive that has at least 50 GB more capacity.

If necessary, you can identify the disks in the volume by following the instructions in Section 3.4.5, Locating Disk Drives in a Volume.

2.Wait until synchronization completes on the new disk and the volume returns to the Optimal state, as indicated in the Adapter Properties window of the SAS2 BIOS CU.

3.Physically replace the other volume disk drive with a drive that has at least 50 GB more capacity.

Page 16

LSI Corporation Confidential August 2010

Image 16
Contents SAS2 Integrated RAID Solution Revision History Table of Contents Table of Contents Introduction to the Integrated RAID Solution FeaturesOverview Enhanced RAID 1EBenefits and Features Introduction Overview of Integrated RAID Mirrored VolumesTypes of mirrored arrays Operation of Mirrored Volumes Typical Integrated Mirroring Implementation Integrated Mirroring Enhanced with Three Disks Mirrored Volume Features SAS2 Integrated RAID Solution User Guide Creating Mirrored Volumes Mirrored Volume Configuration Overview Please wait, invoking SAS Configuration UtilitySelect Create RAID 1 Volume Create New Array window appearsSelect Create RAID 1E Volume Expanding an Integrated Mirroring Volume with OCE Manage Array window appears Select New Array Type window appearsArray on this adapter Following figureManage Hot Spares window appears Smart supportHot Spare status changes to Yes Press C to create the hot spare diskOther Configuration Tasks Follow these steps to activate a selected volume Currently inactivePress Enter Select RAID Properties, and then press EnterFollow these steps to select a boot disk SAS2 Bios CU, select an adapter from the Adapter ListHighlight SAS Topology, and press Enter SAS Topology window appearsBoot Device on SAS Topology Window Volumes can consist of two-to-ten disks Boot disk or as a data diskOverview of Integrated Striping Integrated Striping Description Integrated Striping ExampleCreating Integrated Striping Volumes Creating Integrated Striping VolumesSelect Create RAID 0 Volume Viewing Volume Properties Activating an Array Select Delete Array Alternate device Following figure showsSAS2 Integrated RAID Solution User Guide Hardware and Software Using the SAS2 Integrated RAID Configuration UtilityRequirements Interface Description Commands EFICommand to get the enclosure and slot numbers of a drive GB of capacity on the disk driveFollowing fields of IOC Page 6 specify the configuration MPI2 specification and is specific for SSD drives only VolumeName a user-specified string to identify the volume Appearing while the command is runningSas2ircu controller# delete noprompt Sas2ircu controller# display filename112 Initiator IDDrive Type Enclosure information Enclosure# Logical IDConfiguration has changed or a drive has failed Failed FLD The volume has failedMissing MIS The volume is missing Initializing Init The volume is initializingSas2ircu controller# hotspare delete EnclosureBay Sas2ircu controller# status Volume status Enabled or Disabled  Physical disk I/Os Quiesced or Not quiescedSas2ircu list NoneSas2ircu controller# constchk volumeId noprompt Sas2ircu controller# activate volumeIdSas2ircu controller# logir action filename noprompt