LSI SAS2 manual Revision History

Page 2

Revision History

Version and Date

Description of Changes

 

 

Version 2.0, August 2010

Added new models of supported controllers.

 

 

Version 1.1, August 2009

Applied extensive general editing improvements.

 

 

Version 1.0, July 2009

Initial release of this document.

 

 

LSI, the LSI logo, Fusion-MPT are trademarks or registered trademarks of LSI Corporation or its subsidiaries. All other brand and product names may be trademarks of their respective companies.

LSI Corporation reserves the right to make changes to the product(s) or information disclosed herein at any time without notice. LSI Corporation does not assume any responsibility or liability arising out of the application or use of any product or service described herein, except as expressly agreed to in writing by LSI Corporation; nor does the purchase, lease, or use of a product or service from LSI Corporation convey a license under any patent rights, copyrights, trademark rights, or any other of the intellectual property rights of LSI Corporation or of third parties.

This document contains proprietary information of LSI Corporation. The information contained herein is not to be used by or disclosed to third parties without the express written permission of LSI Corporation.

Corporate Headquarters

Email

Website

Milpitas, CA

globalsupport@lsi.com

www.lsi.com

800-372-2447

 

 

Document Number: DB15-000543-02

 

 

Copyright © 2010 LSI Corporation

 

 

All Rights Reserved

 

 

Image 2
Contents SAS2 Integrated RAID Solution Revision History Table of Contents Table of Contents Overview Introduction to the Integrated RAID SolutionFeatures Enhanced RAID 1EBenefits and Features Types of mirrored arrays Overview of Integrated RAID Mirrored VolumesIntroduction Operation of Mirrored Volumes Typical Integrated Mirroring Implementation Integrated Mirroring Enhanced with Three Disks Mirrored Volume Features SAS2 Integrated RAID Solution User Guide Configuration Overview Creating Mirrored VolumesMirrored Volume Please wait, invoking SAS Configuration UtilitySelect Create RAID 1 Volume Create New Array window appearsSelect Create RAID 1E Volume Expanding an Integrated Mirroring Volume with OCE Array on this adapter Manage Array window appearsSelect New Array Type window appears Following figureHot Spare status changes to Yes Manage Hot Spares window appearsSmart support Press C to create the hot spare diskOther Configuration Tasks Press Enter Follow these steps to activate a selected volumeCurrently inactive Select RAID Properties, and then press EnterHighlight SAS Topology, and press Enter Follow these steps to select a boot diskSAS2 Bios CU, select an adapter from the Adapter List SAS Topology window appearsBoot Device on SAS Topology Window Overview of Integrated Striping Boot disk or as a data diskVolumes can consist of two-to-ten disks Integrated Striping Description Integrated Striping ExampleCreating Integrated Striping Volumes Creating Integrated Striping VolumesSelect Create RAID 0 Volume Viewing Volume Properties Activating an Array Select Delete Array Alternate device Following figure showsSAS2 Integrated RAID Solution User Guide Requirements Using the SAS2 Integrated RAID Configuration UtilityHardware and Software Interface Description Commands EFICommand to get the enclosure and slot numbers of a drive GB of capacity on the disk drive VolumeName a user-specified string to identify the volume Following fields of IOC Page 6 specify the configurationMPI2 specification and is specific for SSD drives only Appearing while the command is runningSas2ircu controller# delete noprompt Sas2ircu controller# display filenameDrive Type 112Initiator ID Enclosure information Enclosure# Logical IDMissing MIS The volume is missing Configuration has changed or a drive has failedFailed FLD The volume has failed Initializing Init The volume is initializingSas2ircu controller# hotspare delete EnclosureBay Sas2ircu controller# statusSas2ircu list  Volume status Enabled or Disabled Physical disk I/Os Quiesced or Not quiesced NoneSas2ircu controller# constchk volumeId noprompt Sas2ircu controller# activate volumeIdSas2ircu controller# logir action filename noprompt