Liebert UPStation GXT General Description, System Description, Features, Standard Components

Page 7

GENERAL DESCRIPTION

Congratulations on your purchase of Liebert's UPStation GXT 6 kVA Maintenance Bypass. As with every Liebert product, we stand behind our quality. If you have any questions concerning this Maintenance Bypass, please feel free to contact your local sales representative, or call the appropriate Technical Support number listed on the back of this manual.

To ensure proper installation and operation of this unit, please read this manual thoroughly.

While installation must be completed by a qualified / certified electrician, general operation may be performed without special training.

SYSTEM DESCRIPTION

The Liebert UPStation GXT 6 kVA Maintenance Bypass is intended for use with the UPStation GXT 6 kVA UPS. Typical applications include supporting workstations, servers, network, telecom or other sensitive electronic equipment.

The UPStation GXT 6 kVA Maintenance Bypass was designed to provide maximum system availability to business-critical equipment. The bypass allows for transfer of connected loads to an alternate power path, allowing full isolation of the UPS. After connected loads are switched to alternate power and the UPS is isolated, the UPS can be turned off and removed from service with no interruption of power to connected loads.

The Configurable Output Distribution was designed to provide maximum flexibility to business-critical equipment.

Various output receptacle options are available from 15 A to 30 A. Hardwire options are also available with a branch rated circuit breaker.

NOTE

The 120V loads need to be balanced on the UPS output. To do this, when connecting 120V equipment to the Maintenance Bypass (MB), start at one end of the MB and fill in toward the other end.

Features

Supports up to 30A loads

Compact design

Highly configurable

Multiple power path indicators

High-speed, break-before-make transfer switch

Standard Components

Provisions for hardwire output

Power indicator lamps

Branch rated circuit breakers

Easily accessible terminal blocks

Options

Field-installable output distribution kits

3

Image 7
Contents UPStation GXT 6kVA Maintenance Bypass Page Table of Contents Page Save These Instructions Important Safety InstructionsGlossary of Symbols Standard Components FeaturesGeneral Description System DescriptionMaintenance Bypass component layout Amp Options Bypass SwitchConfigurable Output Distribution Major ComponentsWiring Preparation Cable InstallationPower Cable Installation Connecting Maintenance Bypass to UPStation GXT6000T GND3 Maintenance Bypass GND1 GND2 120V 240V Output TB4 Diagram for Attaching Unit to Wall WALL-MOUNT DiagramAccessing terminal block Hardwire Output OptionOn Maintenance Bypass Operating ProceduresSpecifications Page Page Company Behind the Products