Liebert PSITM user manual Specifications, UPS specifications

Page 30

Specifications

12.0SPECIFICATIONS

Table 3

UPS specifications

 

 

 

 

 

 

 

 

 

 

 

 

 

Model Number

PS1000RT2-230

PS1440RT2-230

 

PS2200RT2-230

 

PS3000RT2-230

 

PS2200RT2-230E

 

PS3000RT2-230E

 

 

 

 

 

 

Power Rating, VA/W

1000VA/750W

1440VA/1080W

 

2200VA/1650W

 

3000VA/2250W

Dimensions, W x D x H, mm (in)

 

 

 

 

 

 

Unit

87 x 557 x 430

87 x 557 x 430

 

87 x 612 x 430

 

87 x 612 x 430

 

(3.43 x 22 x 17)

(3.43 x 22 x 17)

 

(3.43 x 24.1 x 17)

 

(3.43 x 24.1 x 17)

 

 

 

 

 

Shipping

300 x 706 x 598

300 x 706 x 598

 

333 x 864 x 598

 

333 x 864 x 598

 

(11.8 x 27.8 x 23.5)

(11.8 x 27.8 x 23.5)

 

(13.1 x 34 x 23.5)

 

(13.1 x 34 x 23.5)

 

 

 

 

Weight, kg (lbs)

 

 

 

 

 

 

 

Unit

28 (61.7)

31.0 (68.2)

 

35.0 (77.0)

 

37.0 (81.6)

 

 

 

 

 

 

 

 

 

Shipping

36.6 (80.7)

39.0 (85.8)

 

43.6 (95.9)

 

45.6 (100.5)

 

 

 

 

 

 

 

Input AC Parameters

 

 

 

 

 

 

Rated Input Voltage

 

220/230/240VAC

 

 

 

 

 

 

 

 

 

Surge Protection

 

 

 

660J

 

 

 

 

 

 

 

 

Voltage Range Without

 

158VAC - 283VAC, configurable

 

 

Battery Operation

 

 

 

 

 

 

 

 

 

 

Frequency Range

 

45 - 65 Hz (±0.1 Hz)

 

 

 

 

 

 

 

 

 

 

Input AC Inlet

IEC-320-C14

IEC-320-C14

 

IEC-320-C20

 

IEC-320-C20

 

 

 

 

 

 

 

Output AC Parameters

 

 

 

 

 

 

 

Output Receptacles

(8) IEC-320-C13

(8) IEC-320-C13

 

(8) IEC-320-C13

 

(8) IEC-320-C13

 

 

(1) IEC-320-C19

 

(1) IEC-320-C19

 

 

 

 

 

 

Voltage (Normal mode)

 

220/230/240VAC (configurable) ±10%

 

 

 

 

 

 

Voltage (Battery Mode)

 

220/230/240VAC (configurable);

 

±5% before low battery warning; ±8% after low battery warning

 

 

 

Transfer Time

 

4-6 ms typical

 

 

 

 

 

 

 

 

Waveform

 

 

Sinewave

 

 

 

 

 

Frequency (Normal Mode)

 

45 - 65 Hz (±0.1 Hz)

 

 

 

 

 

Frequency (Battery Mode)

 

50 or 60 Hz (±0.5 Hz); auto sensing

 

 

 

 

 

 

 

 

Overload Warning

 

>100 - 110%

 

 

 

 

 

 

 

 

Overload Shutdown

 

>200% - short circuit; after 15 cycles (normal mode)

 

 

 

 

 

 

 

 

Battery Parameters

 

 

 

 

 

 

 

Type

 

Valve-regulated, nonspillable, lead acid

 

 

 

 

 

 

 

 

QuantityxVoltagexRating

4 x 12V x 7Ah

4 x 12V x 7Ah

 

6 x 12V x 7Ah

 

6 x 12V x 9Ah

 

 

 

 

 

 

Battery Manufacturers

 

CSB, B&B Battery, and EnerSys

 

 

 

 

 

 

 

Backup Time

 

See Table 5 - Battery run times

 

 

Full Load

11

5

 

5

 

6

 

 

 

 

 

 

 

 

 

Half Load

26

16

 

16

 

16

 

 

 

 

 

 

 

Recharge Time

4 hours to 90% of rated capacity, after full discharge into resistive load

 

 

 

 

 

 

 

Environmental

 

 

 

 

 

 

Operating Temperature

 

0°C to + 40°C (+32°F to + 104°F)

 

 

 

 

 

Storage Temperature

 

-15°C to + 40°C (+5°F to + 104°F)

 

 

 

 

 

 

 

Relative Humidity

 

0% to 95%, non-condensing

 

 

 

 

 

 

 

 

Operating Altitude

Up to 2,000m (6,500 ft) at 35°C (95°F)

 

Up to 3,000m (10,000 ft) at 35°C (95°F)

 

without derating

 

without derating

 

 

 

 

Audible Noise

<40 dBA, internal fan(s) Off

 

<40 dBA, internal fan(s) Off

 

<50 dBA, internal fan(s) On

 

<60 dBA, internal fan(s) On

 

 

 

26

Image 30
Contents PowerSure PSI Power AvailabilityPage Table of Contents Figures Important Safety Instructions Safety PrecautionsPage Glossary of Symbols Voltage Programming ButtonIntroduction Front view of UPSAC Input External BatteryRS232 DB-9 Cabinet Connector Port USB PortRelay Major ComponentsInput Automatic Voltage Regulator Battery ChargerBattery Inverter-1000/1440 Models OnlyWHAT’S Included Tower UPS Installation InstallationPreparation Rack-Mount UPS Conversion and Installation Two 2 M4x6 Flat Head Screws Rack Mount HandlesWasher M5x12 Flat Screw Vertical overlay for towerOption 1 Serial Communications RJ11/RJ45 connectionExternal Battery Cabinet Installation Key to Repo switch connections 24 VDC Sense GroundAll indicators illuminated For illustrative purposes only ON/Alarm Silence/Battery Test ButtonControls and Indicators OFF ButtonAC Input Indicator-Green Load Level Indicators-4 green, 1 amberBattery Level Indicators-5 green Buck/Boost Indicator-GreenOver Temp Indicator-Amber Fault Indicator-RedMains power present Within operational limits Normal ModeBuck/Boost Mode Indicator shows UPS in Boost Mode solid greenBattery Indicator illuminated Battery ModeBattery Recharge Operation Battery Indicator flashes greenCommunications DB-9 ConnectorRemote Shutdown Via the DB-9 Connector DB-9 pin assignmentData Line Protection Connectors USB Interface PortUPS Intelligent Communications Voltage Programming Procedure Load Level Indicators Voltage Programming ButtonInput Voltage Output Voltage Setting Range Battery Mode Maintenance Cleaning the UPSBattery Replacement Maintaining BatteriesInternal Battery Replacement Procedure Troubleshooting Status indicatorsTroubleshooting chart Problem Cause SolutionSpecifications UPS specificationsSee Battery run times Environmental Battery cabinet specificationsBattery Parameter Model Number PS1000RT2-230 PS1440RT2-230 PS2200RT2-230Battery run times Page Locations Technical Support/ServiceCompany Behind the Products Asia 23F, Allied Kajima Bldg

PSITM specifications

The Liebert PSITM is an advanced power protection system designed to ensure the reliability and efficiency of critical systems in data centers, industrial applications, and mission-critical environments. As the demand for uninterrupted power supply continues to grow, the Liebert PSI serves as an indispensable asset.

One of the main features of the Liebert PSI is its online double-conversion technology. This method guarantees a continuous supply of clean and stable power to connected loads by converting incoming AC power to DC, then back to AC. This process eliminates power disturbances such as voltage sags, surges, and harmonics, ensuring that sensitive equipment operates without interruption.

In addition to its robust power protection capabilities, the Liebert PSI offers scalable solutions to meet varying power requirements. Ranging from 5 kVA to 40 kVA, it can be configured for single or three-phase operation. This flexibility allows businesses to tailor the system to match their specific needs, whether they are expanding data center operations or simply upgrading existing infrastructure.

Another notable characteristic of the Liebert PSI is its energy efficiency. The unit is designed to operate with a high efficiency of up to 94%, which not only reduces operational costs but also minimizes the environmental impact. Moreover, it features an eco-mode that optimizes energy use during non-critical operations without sacrificing reliability.

The Liebert PSI is equipped with advanced communication and management capabilities. It includes an intuitive LCD display for real-time monitoring, enabling users to access vital information about the unit's performance and status. Additionally, it supports various communication protocols such as SNMP and Modbus, allowing for seamless integration into existing management systems.

Furthermore, the Liebert PSI is designed with an emphasis on modularity, allowing for easy upgrades and maintenance. This modular approach reduces downtime and enhances serviceability, ensuring that the system remains reliable throughout its lifecycle.

In summary, the Liebert PSITM stands out as a comprehensive power protection solution that combines cutting-edge technology, energy efficiency, and user-friendly features. Its commitment to safeguarding critical systems against power disturbances makes it a vital component in the infrastructure of any modern data center or industrial setting.