Liebert PSITM user manual External Battery, AC Input, USB Port, RS232 DB-9 Cabinet Connector Port

Page 9

Introduction

Figure 2 1000 and 1440VA PSI—rear view

 

 

Intellislot Port

Circuit Breaker

Data Line

Output

REPO

Connectors

Receptacles

 

 

 

 

 

 

 

 

INPUT

IN

OUT

 

 

 

 

BREAKER

 

 

 

 

 

 

 

 

 

 

PUSH TO RESET

 

 

 

1

REPO

 

 

 

 

 

3

 

 

 

 

 

2

 

 

 

 

LOAD 1

 

 

 

 

 

4

 

 

 

PHONE / FAX / MODEM / NETWORK

 

 

 

 

 

 

 

 

 

 

 

PROTECTION

 

 

-232

 

 

INPUT

 

 

 

 

 

 

 

 

 

 

 

 

 

LOAD 2

BATTERY CONNECTOR 1440VA/DC 48V/30A 1000VA/DC 48V/20A

+

-

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

External Battery

 

 

 

 

AC Input

USB Port

RS232 (DB-9)

Cabinet Connector

 

Port

 

Figure 3 2200 and 3000VA PSI—rear view

 

 

 

Data Line

Output Circuit

 

 

Intellislot

Input Circuit

Breaker 1

Output

REPO

Port

Connectors

Receptacles

Breaker

 

 

 

 

 

 

 

 

 

 

/ FAX /

 

 

 

 

/

 

 

 

 

 

 

LOAD 1

BATTERY

1

 

 

 

BREAKER

CONNECTOR

2

 

 

 

 

2200V/A/DC 72V30A

3

 

 

 

 

3000V/A/DC 72V40A

 

 

 

 

 

4

 

 

 

10A/260VAC

 

REPO

 

 

IN

OUT

 

 

INTELLISLOT

 

 

LOAD 2

 

 

 

 

BREAKER

 

 

 

 

 

 

RS-232

INPUT

 

 

 

+

 

 

 

 

-

INPUT

 

BREAKER

 

PUSH TO

 

RESET

LOAD 3

USB

AC Input

Output

Output Circuit

External Battery

 

Receptacle

Port

RS232 (DB-9)

 

Breaker 2

Cabinet Connector

 

Port

 

 

 

5

Image 9
Contents Power Availability PowerSure PSIPage Table of Contents Figures Safety Precautions Important Safety InstructionsPage Voltage Programming Button Glossary of SymbolsFront view of UPS IntroductionRS232 DB-9 Cabinet Connector Port External BatteryAC Input USB PortRelay Major ComponentsInput Battery Battery ChargerAutomatic Voltage Regulator Inverter-1000/1440 Models OnlyWHAT’S Included Tower UPS Installation InstallationPreparation Two 2 M4x6 Flat Head Screws Rack Mount Handles Rack-Mount UPS Conversion and InstallationVertical overlay for tower Washer M5x12 Flat ScrewRJ11/RJ45 connection Option 1 Serial CommunicationsKey to Repo switch connections 24 VDC Sense Ground External Battery Cabinet InstallationControls and Indicators ON/Alarm Silence/Battery Test ButtonAll indicators illuminated For illustrative purposes only OFF ButtonBattery Level Indicators-5 green Load Level Indicators-4 green, 1 amberAC Input Indicator-Green Buck/Boost Indicator-GreenFault Indicator-Red Over Temp Indicator-AmberBuck/Boost Mode Normal ModeMains power present Within operational limits Indicator shows UPS in Boost Mode solid greenBattery Recharge Operation Battery ModeBattery Indicator illuminated Battery Indicator flashes greenRemote Shutdown Via the DB-9 Connector DB-9 ConnectorCommunications DB-9 pin assignmentData Line Protection Connectors USB Interface PortUPS Intelligent Communications Voltage Programming Procedure Load Level Indicators Voltage Programming ButtonInput Voltage Output Voltage Setting Range Battery Mode Battery Replacement Cleaning the UPSMaintenance Maintaining BatteriesInternal Battery Replacement Procedure Status indicators TroubleshootingProblem Cause Solution Troubleshooting chartUPS specifications SpecificationsBattery Parameter Battery cabinet specificationsSee Battery run times Environmental Model Number PS1000RT2-230 PS1440RT2-230 PS2200RT2-230Battery run times Page Company Behind the Products Technical Support/ServiceLocations Asia 23F, Allied Kajima Bldg

PSITM specifications

The Liebert PSITM is an advanced power protection system designed to ensure the reliability and efficiency of critical systems in data centers, industrial applications, and mission-critical environments. As the demand for uninterrupted power supply continues to grow, the Liebert PSI serves as an indispensable asset.

One of the main features of the Liebert PSI is its online double-conversion technology. This method guarantees a continuous supply of clean and stable power to connected loads by converting incoming AC power to DC, then back to AC. This process eliminates power disturbances such as voltage sags, surges, and harmonics, ensuring that sensitive equipment operates without interruption.

In addition to its robust power protection capabilities, the Liebert PSI offers scalable solutions to meet varying power requirements. Ranging from 5 kVA to 40 kVA, it can be configured for single or three-phase operation. This flexibility allows businesses to tailor the system to match their specific needs, whether they are expanding data center operations or simply upgrading existing infrastructure.

Another notable characteristic of the Liebert PSI is its energy efficiency. The unit is designed to operate with a high efficiency of up to 94%, which not only reduces operational costs but also minimizes the environmental impact. Moreover, it features an eco-mode that optimizes energy use during non-critical operations without sacrificing reliability.

The Liebert PSI is equipped with advanced communication and management capabilities. It includes an intuitive LCD display for real-time monitoring, enabling users to access vital information about the unit's performance and status. Additionally, it supports various communication protocols such as SNMP and Modbus, allowing for seamless integration into existing management systems.

Furthermore, the Liebert PSI is designed with an emphasis on modularity, allowing for easy upgrades and maintenance. This modular approach reduces downtime and enhances serviceability, ensuring that the system remains reliable throughout its lifecycle.

In summary, the Liebert PSITM stands out as a comprehensive power protection solution that combines cutting-edge technology, energy efficiency, and user-friendly features. Its commitment to safeguarding critical systems against power disturbances makes it a vital component in the infrastructure of any modern data center or industrial setting.