Liebert PSITM user manual Battery run times

Page 32

 

 

 

 

 

 

Specifications

Table 5

Battery run times

 

 

 

 

 

 

 

 

 

 

 

 

 

Load%

1000VA

1440VA

2200VA

3000VA

 

 

5%

174

138

171

177

 

 

10%

118

79

73

91

 

 

20%

65

45

47

47

 

 

30%

41

28

26

28

Internal

 

40%

37

24

23

22

Battery

 

50%

26

16

16

16

(minutes)

 

60%

24

14

13

14

 

 

70%

18

10

10

10

 

 

80%

16

9

8

9

 

 

90%

12

6

6

7

 

 

100%

11

5

5

6

 

 

5%

513

409

542

542

 

 

10%

305

265

266

257

Internal

 

20%

248

188

185

148

 

30%

177

125

135

141

Battery + 1

 

 

 

 

 

 

 

40%

139

104

122

99

External

 

 

50%

119

72

99

67

Battery

 

 

60%

98

59

75

53

Cabinet

 

(minutes)

 

70%

75

45

55

45

 

 

80%

63

40

49

39

 

 

90%

53

35

44

34

 

 

100%

46

30

40

29

 

 

5%

1001

828

 

 

10%

565

461

493

444

Internal

 

20%

409

283

291

249

 

30%

283

219

222

168

Battery + 2

 

 

 

 

 

 

 

40%

248

177

194

148

External

 

 

50%

209

133

150

129

Battery

 

 

60%

166

122

137

114

Cabinet

 

(minutes)

 

70%

136

98

122

92

 

 

80%

127

84

107

71

 

 

90%

110

64

92

56

 

 

100%

98

56

77

52

 

 

5%

1174

1001

 

 

10%

1001

655

590

Internal

 

20%

565

409

493

300

 

30%

409

283

283

240

Battery + 3

 

 

 

 

 

 

 

40%

305

257

266

213

External

 

 

50%

274

209

222

168

Battery

 

 

60%

248

166

185

144

Cabinet

 

(minutes)

 

70%

209

136

156

129

 

 

80%

188

125

141

116

 

 

90%

145

110

131

101

 

 

100%

136

95

120

88

 

 

5%

1174

 

 

10%

1174

828

Internal

 

20%

828

565

590

444

 

30%

513

357

395

283

Battery + 4

 

 

 

 

 

 

 

40%

461

292

300

266

External

 

 

50%

305

257

274

222

Battery

 

 

60%

283

230

240

179

Cabinet

 

(minutes)

 

70%

257

188

203

150

 

 

80%

239

156

173

139

 

 

90%

209

136

156

129

 

 

100%

188

125

144

118

NOTE

Approximate discharge times are in minutes and at 25°C (77°F) with resistive load.

28

Image 32
Contents PowerSure PSI Power AvailabilityPage Table of Contents Figures Important Safety Instructions Safety PrecautionsPage Glossary of Symbols Voltage Programming ButtonIntroduction Front view of UPSExternal Battery RS232 DB-9 Cabinet Connector PortAC Input USB PortInput RelayMajor Components Battery Charger BatteryAutomatic Voltage Regulator Inverter-1000/1440 Models OnlyWHAT’S Included Preparation Tower UPS InstallationInstallation Rack-Mount UPS Conversion and Installation Two 2 M4x6 Flat Head Screws Rack Mount HandlesWasher M5x12 Flat Screw Vertical overlay for towerOption 1 Serial Communications RJ11/RJ45 connectionExternal Battery Cabinet Installation Key to Repo switch connections 24 VDC Sense GroundON/Alarm Silence/Battery Test Button Controls and IndicatorsAll indicators illuminated For illustrative purposes only OFF ButtonLoad Level Indicators-4 green, 1 amber Battery Level Indicators-5 greenAC Input Indicator-Green Buck/Boost Indicator-GreenOver Temp Indicator-Amber Fault Indicator-RedNormal Mode Buck/Boost ModeMains power present Within operational limits Indicator shows UPS in Boost Mode solid greenBattery Mode Battery Recharge OperationBattery Indicator illuminated Battery Indicator flashes greenDB-9 Connector Remote Shutdown Via the DB-9 ConnectorCommunications DB-9 pin assignmentUPS Intelligent Communications Data Line Protection ConnectorsUSB Interface Port Input Voltage Output Voltage Setting Range Battery Mode Voltage Programming ProcedureLoad Level Indicators Voltage Programming Button Cleaning the UPS Battery ReplacementMaintenance Maintaining BatteriesInternal Battery Replacement Procedure Troubleshooting Status indicatorsTroubleshooting chart Problem Cause SolutionSpecifications UPS specificationsBattery cabinet specifications Battery ParameterSee Battery run times Environmental Model Number PS1000RT2-230 PS1440RT2-230 PS2200RT2-230Battery run times Page Technical Support/Service Company Behind the ProductsLocations Asia 23F, Allied Kajima Bldg

PSITM specifications

The Liebert PSITM is an advanced power protection system designed to ensure the reliability and efficiency of critical systems in data centers, industrial applications, and mission-critical environments. As the demand for uninterrupted power supply continues to grow, the Liebert PSI serves as an indispensable asset.

One of the main features of the Liebert PSI is its online double-conversion technology. This method guarantees a continuous supply of clean and stable power to connected loads by converting incoming AC power to DC, then back to AC. This process eliminates power disturbances such as voltage sags, surges, and harmonics, ensuring that sensitive equipment operates without interruption.

In addition to its robust power protection capabilities, the Liebert PSI offers scalable solutions to meet varying power requirements. Ranging from 5 kVA to 40 kVA, it can be configured for single or three-phase operation. This flexibility allows businesses to tailor the system to match their specific needs, whether they are expanding data center operations or simply upgrading existing infrastructure.

Another notable characteristic of the Liebert PSI is its energy efficiency. The unit is designed to operate with a high efficiency of up to 94%, which not only reduces operational costs but also minimizes the environmental impact. Moreover, it features an eco-mode that optimizes energy use during non-critical operations without sacrificing reliability.

The Liebert PSI is equipped with advanced communication and management capabilities. It includes an intuitive LCD display for real-time monitoring, enabling users to access vital information about the unit's performance and status. Additionally, it supports various communication protocols such as SNMP and Modbus, allowing for seamless integration into existing management systems.

Furthermore, the Liebert PSI is designed with an emphasis on modularity, allowing for easy upgrades and maintenance. This modular approach reduces downtime and enhances serviceability, ensuring that the system remains reliable throughout its lifecycle.

In summary, the Liebert PSITM stands out as a comprehensive power protection solution that combines cutting-edge technology, energy efficiency, and user-friendly features. Its commitment to safeguarding critical systems against power disturbances makes it a vital component in the infrastructure of any modern data center or industrial setting.