Liebert PSITM user manual Figures

Page 4

9.0 VOLTAGE PROGRAMMING PROCEDURE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .21 10.0 MAINTENANCE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .22

10.1 Cleaning the UPS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22

10.2 Maintaining Batteries . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22

10.3 Battery Replacement . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22

10.3.1 Internal Battery Replacement Procedure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23

11.0 TROUBLESHOOTING . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .24 12.0 SPECIFICATIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .26

 

FIGURES

 

Figure 1

Front view of UPS

. 4

Figure 2

1000 and 1440VA PSI—rear view

. 5

Figure 3

2200 and 3000VA PSI—rear view

. 5

Figure 4

Line diagram of PowerSure PSI 1000VA & 1440VA

. 6

Figure 5

Line diagram of PowerSure PSI 2200VA & 3000VA

. 6

Figure 6

Support base for tower configuration

. 9

Figure 7

Rack mount handles

10

Figure 8

Fixed rails with inner members extended

10

Figure 9

Rack mounting rails and slide assemblies

11

Figure 10

REPO switch connections

13

Figure 11

Load level indicators—4 green, 1 amber

15

Figure 12

Battery level indicators—5 green

15

Figure 13

Normal mode operation with 26-50% load

17

Figure 14

Buck/Boost mode operation with 51-75% load and 21-40% battery capacity

17

Figure 15

Battery mode at 61 – 80% battery capacity

18

Figure 16

Low Battery mode

18

Figure 17

Load Level Indicators

21

Figure 18

Battery replacement procedure

23

Figure 19

Status indicators

24

 

TABLES

 

Table 1

DB-9 pin assignment

19

Table 2

Troubleshooting chart

25

Table 3

UPS specifications

26

Table 4

Battery cabinet specifications

27

Table 5

Battery run times

28

ii

Image 4
Contents PowerSure PSI Power AvailabilityPage Table of Contents Figures Important Safety Instructions Safety PrecautionsPage Glossary of Symbols Voltage Programming ButtonIntroduction Front view of UPSExternal Battery RS232 DB-9 Cabinet Connector PortAC Input USB PortMajor Components RelayInput Battery Charger BatteryAutomatic Voltage Regulator Inverter-1000/1440 Models OnlyWHAT’S Included Installation Tower UPS InstallationPreparation Rack-Mount UPS Conversion and Installation Two 2 M4x6 Flat Head Screws Rack Mount HandlesWasher M5x12 Flat Screw Vertical overlay for towerOption 1 Serial Communications RJ11/RJ45 connectionExternal Battery Cabinet Installation Key to Repo switch connections 24 VDC Sense GroundON/Alarm Silence/Battery Test Button Controls and IndicatorsAll indicators illuminated For illustrative purposes only OFF ButtonLoad Level Indicators-4 green, 1 amber Battery Level Indicators-5 greenAC Input Indicator-Green Buck/Boost Indicator-GreenOver Temp Indicator-Amber Fault Indicator-RedNormal Mode Buck/Boost ModeMains power present Within operational limits Indicator shows UPS in Boost Mode solid greenBattery Mode Battery Recharge OperationBattery Indicator illuminated Battery Indicator flashes greenDB-9 Connector Remote Shutdown Via the DB-9 ConnectorCommunications DB-9 pin assignmentUSB Interface Port Data Line Protection ConnectorsUPS Intelligent Communications Load Level Indicators Voltage Programming Button Voltage Programming ProcedureInput Voltage Output Voltage Setting Range Battery Mode Cleaning the UPS Battery ReplacementMaintenance Maintaining BatteriesInternal Battery Replacement Procedure Troubleshooting Status indicatorsTroubleshooting chart Problem Cause SolutionSpecifications UPS specificationsBattery cabinet specifications Battery ParameterSee Battery run times Environmental Model Number PS1000RT2-230 PS1440RT2-230 PS2200RT2-230Battery run times Page Technical Support/Service Company Behind the ProductsLocations Asia 23F, Allied Kajima Bldg

PSITM specifications

The Liebert PSITM is an advanced power protection system designed to ensure the reliability and efficiency of critical systems in data centers, industrial applications, and mission-critical environments. As the demand for uninterrupted power supply continues to grow, the Liebert PSI serves as an indispensable asset.

One of the main features of the Liebert PSI is its online double-conversion technology. This method guarantees a continuous supply of clean and stable power to connected loads by converting incoming AC power to DC, then back to AC. This process eliminates power disturbances such as voltage sags, surges, and harmonics, ensuring that sensitive equipment operates without interruption.

In addition to its robust power protection capabilities, the Liebert PSI offers scalable solutions to meet varying power requirements. Ranging from 5 kVA to 40 kVA, it can be configured for single or three-phase operation. This flexibility allows businesses to tailor the system to match their specific needs, whether they are expanding data center operations or simply upgrading existing infrastructure.

Another notable characteristic of the Liebert PSI is its energy efficiency. The unit is designed to operate with a high efficiency of up to 94%, which not only reduces operational costs but also minimizes the environmental impact. Moreover, it features an eco-mode that optimizes energy use during non-critical operations without sacrificing reliability.

The Liebert PSI is equipped with advanced communication and management capabilities. It includes an intuitive LCD display for real-time monitoring, enabling users to access vital information about the unit's performance and status. Additionally, it supports various communication protocols such as SNMP and Modbus, allowing for seamless integration into existing management systems.

Furthermore, the Liebert PSI is designed with an emphasis on modularity, allowing for easy upgrades and maintenance. This modular approach reduces downtime and enhances serviceability, ensuring that the system remains reliable throughout its lifecycle.

In summary, the Liebert PSITM stands out as a comprehensive power protection solution that combines cutting-edge technology, energy efficiency, and user-friendly features. Its commitment to safeguarding critical systems against power disturbances makes it a vital component in the infrastructure of any modern data center or industrial setting.