1152700 Issue 1 February 2001 Section 2 Operation and Maintenance

DLP-712

Page 5 of 8

Cellworx Vision: Error

 

 

X

Validation failed. Unable to determine card type for slot 8 in the new EPS NE. It is possible that the

shelf controller has not yet had enough time to discover the cards in the shelf. You may retry or cancel this procedure. Note that if you cancel, you will need to reboot the EPS shelf controller(s) before attempting

to re-add this EPS.

OK

0026-055

Figure 712-5. Add EPS NE Error Message

Cellworx Vision: Add EPS NE - Connect to Ring

X

Physically connect the expansion network element to the ring network element.

Cancel

Next >>

10889-A

Figure 712-6. Cellworx Vision Add EPS NE - Connect to Ring

Cellworx Vision: Add EPS NE - Wait for Bootup

X

Waiting for expansion node to boot...

Normal boot time should not exceed 5 minutes.

Elapsed time: 9

Cancel

10895-B

Figure 712-7. Cellworx Vision Add EPS NE - Wait for Bootup

Cellworx Vision: Add EPS NE - Boot Time Exceeded

X

Normal boot time for the network element has been exceeded. This could be the result of a communication failure with the network element. Please check all cables and the network element's status via craft interface if necessary.

Retry

Quit

10888-A

Figure 712-8. Add NE Boot Time Exceeded Window

Page 2-103

2000, ADC Telecommunications, Inc.

Page 123
Image 123
ADC Release 3.1 user manual Add EPS NE Error Message