1152700Issue 1 February 2001 Section 2 Operations and Maintenance

TAP-100

Page 20 of 23

Table 4-1. Alarm Identifications, continued

ALARM MESSAGE

SEVERITY

IMPACT

DESCRIPTION

SUGGESTED COURSE OF ACTION

Unavailable

Seconds

Path

Threshold

Crossing

Alert

UAS-PTca

Informational Alert

Service Degradation

Unavailable seconds threshold crossing alert for path layer. Path layer was unavailable for more seconds than the threshold was set for. UAS overrides all other error counts.

Check input source and transmitter at far end node.

Unavailable

Seconds

Threshold

Crossing

Alert

UASTca

Informational Alert

Service Degradation

T3 unavailable seconds threshold crossing alert. T3 signal was unavailable for more seconds than the threshold was set for. UAS overrides all other error counts.

Check input source.

1.After determining the alarm type, locate the associated interface in Figure-1 below to determine each alarm type origination point in an NE.

Page 2-439

© 2000, ADC Telecommunications, Inc.

Page 483
Image 483
ADC Release 3.1 user manual Unavailable Seconds Path Threshold Crossing Alert, Unavailable Seconds Threshold Crossing Alert