1152700 • Issue 1 • February 2001 • Section 2 Operations and Maintenance
DLP-704
Page 1 of 2
CONNECT NMS OR
Summary: This procedure provides instructions for connecting an external Network Management System (NMS) or
Caution: Modules can be damaged by static electrical discharge. Before handling any modules connect your wrist to an equipment ground using an approved
1.If not already equipped and verified, equip the customer LAN cable with an RJ45X male connector and verify the connector wiring per Figure
2.Route the LAN cable to the lower right side of the Cellworx STN shelf (facing the rear), to terminate at the working NMIC EIM in slot 2. Refer to Figure
3.Dress in the cable leaving enough slack to reach the RJ45X jack on the EIM. Cable ties may be used to attach the cables to the tie bar along the bottom of the air intake baffle. Verify that enough strain relief and maintenance loop are provided.
4.Seat the RJ45X connector into the NMIC EIM RJ45X LAN jack. Verify the latch catches by gently tugging once or twice on the cable.
5.The NMS end of the cable should then be connected to the
Stop! You have completed this procedure.
| PIN | FUNCTION | |
1 | 1 | TRANSMIT + | |
2 | TRANSMIT | ||
| |||
| 3 | RECEIVE + | |
| 4 | NOT USED | |
8 | 5 | NOT USED | |
6 | RECEIVE | ||
RJ45 JACK | 7 | NOT USED | |
8 | NOT USED | ||
| |||
|
|
Figure 704-1. NMIC EIM RJ45 Jack Pin Out