1152700 Issue 1 February 2001 Section 2 Operation and Maintenance

DLP-752

Page 3 of 4

Table 752-1. 155 SM/MM CRS Card Configuration Options, continued

SELECTION

Transmit Timing Source

Do Not Use for Sync

Enable Signal Degrade

Signal Degrade BER Threshold

Medium Type

Loopback

Towards

Line Coding

Line Type

DEFAULT

System

False

Not Selected

5

SONET

None

NRZ

Card Dependant

OPTIONS

System

Received

Selected (True) Non-selected (False)

Selected

Not Selected

5 through 9

SONET

SDH

None

Terminal

Facility

SonetOther sonetShortSingleMode sonetLongSingleMode sonetMultiMode

DEFINITIONS

Uses Primary timing reference.

Uses clock derived from incoming receive fiber (also known as Line-Timing).

Outputs DUS (Do not Use for Sync) in the S1 byte of the SONET overhead.

Enables a protection switch of the traffic if the input signal strength drops below tolerable levels set by the user in the BER threshold selection.

Defines the number of bit errors the port can incur before a signal degrade occurs and generates an alarm message and probably protection switch.

Synchronous Optical Network, US standard for transporting data over fiber.

Synchronous Digital Hierarchy, European standard for transporting data over fiber.

No loopback is requested or active.

A loopback has been activated sending the signal back to the terminal side.

A loopback has been activated sending the signal back to the facility side.

Not configurable by user.

Not configurable by user, dependant on card type inserted.

Transmit Path Trace

SELECTION

User

 

 

 

 

 

User can define a unique ID to this port for

defined

 

 

 

 

 

identification purposes on SM cards only.

 

Table 752-2. ATM Interface Configuration Options

 

 

 

 

 

 

 

 

 

DEFAULT

 

 

OPTIONS

 

 

DEFINITIONS

 

 

 

 

 

 

 

 

Interface Name

Loopback Location Code

<default>

All 1s

Alphanumeric

Alphanumeri c

User defined, up to 20 alphanumeric characters.