1152700 • Issue 1 • February 2001 • Section 2 Operations and Maintenance
Page 4 of 10
FIBER
ROUTING
FLANGES
Figure 701-4. Fiber Routing
B.Fiber Connection
Note: DO NOT LOOK INTO THE ENDS OF ANY FIBER OPTIC CABLES.
8.If the cards are fully seated into the Cellworx STN backplane, disengage them by pulling back the ejector ears on the upper and lower ends of the card faceplate. See Figure
9.Clean the fiber connectors per the instructions provided in section C of this proceedure.
10.Connect the fibers to the optical connectors using Figure
11.Once the fibers are connected, route them up through the fiber clip equipped at the top of the faceplate as shown in Figure
12.Seat the card into the backplane by sliding it into the card cage until the ejector ears catch the shelf trough. Fully seat the card by pressing the ejector ears towards the faceplate until they lock into place. Do not force the cards into the backplane. If excessive resistance is felt, remove the card and check for obstructions and proper alignment in card guides. Once card is seated, give a firm push to insure good contact with the backplane.
Page
© 2000, ADC Telecommunications, Inc.