SET / RETRIEVE OPTICAL PORT PERFORMANCE MONITORING STATISTICS
Summary: This procedure describes the steps required to successfully set or retrieve the performance monitoring statistics for specified optical interface ports within a Cellworx STN network. An optical port may reside on a 2488 RIC, 622 RIC, 155 RIC, or 155 SM/MM CRS card. This procedure assumes the user has already accessed the GUI and accessed the Performance Monitoring Statistics window per
1.Select an NE from the list of NEs in the “Resource” section of the window. Refer to Figure
2.Select a slot/card type in the “Slot/Card Type” section of the window and all available ports will appear in the third window. Multiple slots may be selected.
3.Select the slot(s)/port(s) desired in the “Port” section of the window to display the performance monitoring layers in the “Layer” section of the window. Multiple ports may also be selected.
4.Select the layer or layers to be retrieved in the “Layer” section of the window. If a RIC or 155 CRS card was selected, SONET will be available in the PM layer window. If SONET is not available, return to step 2 of this procedure and select the proper optical interface card. ATM Transmission Convergence (TC) will also be selectable.
5.Select the time period for the report from the Interval selection window on the right. If multiple interfaces were selected, only a single time interval may be selected. If a single interface was selected, the user may specify several historical time periods to retrieve for the report. The current selection will retrieve any errors that are logged for the interface(s) specified. In no instance may the current interval and a history interval be selected at the same time.
6.Select the Apply button once all selections have been specified for the performance report. The Performance Monitoring Data window appears displaying any error counts for each error type. Refer to Figure
7.If SONET Layer was selected for the report, the Section, Line, and Path errors are accessed separately using the tabs at the top of the window. Error types reported are listed in Table