1152700Issue 1 February 2001 Section 2 Operations and Maintenance

TAP-100

Page 8 of 23

Table 4-1. Alarm Identifications, continued

ALARM MESSAGE

 

SEVERITY

 

IMPACT

 

 

 

 

 

 

 

 

 

DESCRIPTION

 

SUGGESTED COURSE OF ACTION

 

 

 

 

 

 

 

 

Errored

Seconds

Line Far

End

Threshold

Crossing

Alert

ES-LFETca

Information

Service

al Alert

Degradation

 

 

Errored seconds violations threshold crossing alert for line layer at far end. A one second interval in the transmission to the far end target NE has had an error at the line layer causing an Errored Second Line (ESL). ESL errors have exceeded the user definable threshold level.

Retrieve PM reports to check for Errored Seconds Section Violations (ESS) which identify problem cards/ports across the network. Check input levels and signal sources. Increase threshold settings if necessary. Check local requirements for proper levels.

Errored

Information

Service

Seconds

al Alert

Degradation

Line

 

 

Threshold

 

 

Crossing

 

 

Alert

 

 

ES-Ltca

 

 

 

 

 

Errored seconds violations threshold crossing alert for line layer at local NE. A one second interval in the transmission from the far end originating NE has had an error at the line layer causing an Errored Second Line (ESL). ESL errors have exceeded the user definable threshold level (OC-N interface only).

Retrieve PM reports to check for Errored Seconds Section Violations (ESS) which identify problem cards/ports across the network. Increase threshold settings if necessary. Check local requirements for proper levels.

Errored

Information

Service

Seconds

al Alert

Degradation

Path Far

 

 

End

 

 

Threshold

 

 

Crossing

 

 

Alert

 

 

ES-PFETca

 

 

 

 

 

Errored seconds violations threshold crossing alert for path layer at far end. A one second interval in the transmission to the far end target NE has had an error at the path layer causing an Errored Second Path (ESP). ESP errors have exceeded the user definable threshold level (OC-N interface only).

Retrieve PM reports to check for Errored Seconds Section Violations (ESS) which identify problem cards/ports across the network. Check input levels and signal sources. Increase threshold settings if necessary. Check local requirements for proper levels.

Errored

Information

Service

Seconds

al Alert

Degradation

Path

 

 

Threshold

 

 

Crossing

 

 

Alert

 

 

ES-Ptca

 

 

 

 

 

ES violations threshold crossing alert for path layer at local NE. A one second interval in the transmission from the far end originating NE has had an error at the path layer causing an Errored Second Path (ESP). ESP errors have exceeded the user definable threshold level.

Retrieve PM reports to check for Errored Seconds Section Violations (ESS) which identify problem cards/ports across the network. Check input levels and signal sources. Increase threshold settings if necessary. Check local requirements for proper levels.

(continued)

Page 2-427