1152700 • Issue 1 • February 2001 • Section 2 Operation and Maintenance
Page 1 of 3
SET 155 RING INTERFACE CARD (RIC) CONFIGURATION
Summary: This procedure details the steps required to set the 155 Ring Interface Card configurations utilizing the Cellworx STN Phase 3.1 shelf level Graphical User Interface (GUI). User must have the GUI launched and accessed the shelf level GUI display per
1.Double click on the 155 RIC located in slot 16 or 17 in the shelf level GUI “Chassis View”at the top of the window.
2.Set the configuration options for the card and port using Table
3.Select the Apply button at the bottom of the window to send the new configuration data to the shelf controller.
Note: Selecting Chassis View will return the user to the previous window without closing the 155 RIC window. Selecting Refresh will update the current window display and all the selections last recorded by the Shelf Controller card. Selecting Close will close this window and return the user to the Chassis View window.
4.Repeat steps 1 through 3 for the second 155 RIC card installed in the shelf.
Stop! You have completed this procedure.
Page