1152700 Issue 1 February 2001 Section 2 Operation and Maintenance

DLP-726

Page 2 of 4

THRESHOLD CONFIGURATION

9.Users may specify error counts required to trip a system alarm by clicking on the Configure Thresholds button at the bottom of the PM Data window. This will bring up a Performance Monitoring Configuration window similar to Figure 726-3.

10.To configure the thresholds, place the cursor in the individual count boxes and type in the new threshold value. Do this for all the thresholds to be set in the Section, Line, and Path tabs. Refer to Table 726-1 for valid values. Once all counts are entered in each box, select the Apply button at the bottom of the screen to send the new data to the database. The Apply button includes each tab in the request.

Stop! You have completed this procedure.

 

SELECT AN NE FOR PM

SELECT A SLOT AND CARD

SELECT THE PORT(S) DESIRED

SELECT THE PM LAYER(S)

SELECT THE CURENT

 

RETRIEVAL AND THE SLOT

TYPE, INDIVIDUAL OR

TO DISPLAY THE LAYERS

TO BE RETRIEVED.

COUNT OR A HISTORICAL

 

AND CARD TYPES IN THE

MULTIPLE, TO DISPLAY THE

AVAILABLE IN THE NEXT

 

 

TIME PERIOD FOR ONE

 

 

 

 

SHELF WILL BE DISPLAYED

PORTS IN THE NEXT WINDOW.

WINDOW.

 

 

SLOT/PORT. USER CANNOT

 

IN THE NEXT WINDOW.

 

 

 

 

 

 

SELECT CURRENT AND A

 

 

 

 

 

 

 

 

 

 

HISTORICAL AT THE SAME

 

 

 

 

 

 

 

 

 

 

TIME.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Cellworx Vision: Performance Monitoring -

Statistics

 

 

 

 

 

 

 

X

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Resource: NE-1

Slot / Card Type

Port

Layer

Interval

NE-1 Cellworx1

Slot 17 / 622 Ring

Slot 16 / Port 1

Sonet

current

00:00-00:15

NE-2 Cellworx2

Slot 16 / 622 Ring

Slot 16 / Port 2

DS1/E1

00:15-00:30

NE-3 Cellworx3

Slot 5 / T3 TMUX Multi 1

Slot 17 / Port 1

DS3

00:30-00:45

 

Slot 6 / 155 SM CRS

Slot 17 / Port 2

PLCP

 

Slot 7 / 155 SM CRS

Slot 5 / Port 1

ATM / TC

00:45-01:00

 

Slot 8 / 155 SM CRS

- Channel 1

AAL1

01:00-01:15

 

Slot 9 / 155 SM CRS

- Channel 2

 

01:15-01:30

 

Slot 10 / T3 CRS

- Channel 3

 

01:30-01:45

 

Slot 11 / T3 CRS

- Channel 4

 

01:45-02:00

 

Slot 12 / T1 Multi 1

- Channel 5

 

0200 - 02:15

 

Apply

 

 

Close

 

 

 

 

11743-D

SELECT TO RETRIEVE PM

CLOSES PM STATISTICS

DATA FOR SELECTED

WINDOW.

PARAMETERS.

 

Figure 726-1. Performance Monitoring – Selection Window

Page 2-144

2000, ADC Telecommunications, Inc.

Page 164
Image 164
ADC Release 3.1 user manual Threshold Configuration, Performance Monitoring Selection Window