1152700 Issue 1 February 2001 Section 2 Operation and Maintenance

DLP-727

Page 3 of 4

MONTYPE

CV-L

ES-L

CV-Pbit

ES-Pbit

UAS

SEFS

CV-Cbit

ES-Cbit

SES-Cbit

SES-Pbit

ES

SES

UAS

BES

SEFS

DM

Table 727-1. T3 TMUX Multi 1 Performance Monitoring Values

MAX 15 MIN. THRESH

 

COMMENTS

 

16383

 

Sets a count of Line Code Violations that the port can incur

 

 

 

before the system declares a TCA.

 

900

 

Sets a count of Line Errored Seconds that the port can

 

 

 

incur before the systems declares a TCA.

 

16383

 

Sets a count of Parity bit Code Violation that the port can

 

 

 

incur before the systems declares a TCA.

 

900

 

Sets a count of Parity bit Errored Seconds that the port can

 

 

 

incur before the systems declares a TCA.

 

900

 

Sets a count of Unavailable Seconds that the port can incur

 

 

 

before the systems declares a TCA.

 

900

 

Sets a count of Severely Errored Frame Seconds that the

 

 

 

port can incur before the systems declares a TCA.

 

16383

 

Sets a count of Cbit (Calculated parity bit of M-frame does

 

 

 

not match received parity bits) Code Violation that the port

 

 

 

can incur before the systems declares a TCA.

 

900

 

Sets a count of Cbit Errored Seconds that the port can incur

 

 

 

before the systems declares a TCA.

 

900

 

Sets a count of Cbit Severely Errored Seconds that the port

 

 

 

can incur before the systems declares a TCA.

 

900

 

Sets a count of Pbit Severely Errored Seconds that the port

 

 

 

can incur before the systems declares a TCA.

 

900

 

Sets a count of errored seconds that the port can incur

 

 

 

before creating a TCA on the system. Error seconds

 

 

 

determined as number of seconds FE>=1, SEF >=1, or any

 

 

 

Cellworx Vision/AIS condition.

 

900

 

Sets a count of line severely errored seconds that the port

 

 

 

can incur before creating a TCA on the system. SES is

 

 

 

determined as the number of seconds CV-L >=1547 or

 

 

 

LOS (Loss of Signal) >=1.

 

900

 

Sets a count of unavailable seconds that the port can incur

 

 

 

before creating a TCA on the system. UAS determined as

 

 

 

the number of seconds that the path is unavailable.

 

900

 

Sets a count of Burst Errored Seconds that the port can

 

 

 

incur before creating a TCA on the system.

 

900

 

Sets a count of severely errored frame seconds that the port

 

 

 

can incur before creating a TCA on the system. SEFS

 

 

 

determined when SEF >=1.

 

15

 

Sets a count of minutes that the port can incur a signal

 

 

 

degradation before creating a TCA on the system.

 

 

 

(continued)

Page 2-149

2000, ADC Telecommunications, Inc.

Page 169
Image 169
ADC Release 3.1 user manual Cv-L Es-L, UAS Sefs, SES UAS BES Sefs, T3 Tmux Multi 1 Performance Monitoring Values