ADC Release 3.1 user manual Delete a Cellworx STN Expansion Shelf EPS

Models: Release 3.1

1 489
Download 489 pages 5.8 Kb
Page 238
Image 238

1152700 Issue 1 February 2001 Section 2 Operation and Maintenance

DLP-746

Page 1 of 3

DELETE A CELLWORX STN EXPANSION SHELF (EPS)

Summary: This procedure details the steps required to delete a Cellworx STN shelf that is currently being utilized in a network as an expansion shelf (STN-EPS). The user should ensure all connections to the EPS NE are deleted before attempting this procedure.

1.Select the NE to be deleted using the left mouse button. A white ring surrounds the NE.

2.Access the Remove EPS NE Task Overview window using the left mouse button to select Configuration, Topology, and Remove Expansion Shelf Network Element (or using the direct selection keys, Alt+C, Alt+T, then Alt+X). Refer to Figure 746-1.

3.The task overview window appears as shown in Figure 746-2and the system requests verification that this task is to be initiated. Refer to Figure 746-3. Click on Yes in the confirmation window to continue or No to abort this procedure.

4.Step 1 indicates that the system is checking for any existing connections terminating at the EPS. If any connections are found, the user must first delete them before continuing. Refer to DLP-739to delete connections.

5.Step 3 of the task overview instructs the user to reconfigure the EPS and RNE interfaces as non-SEPIs (Shelf Expansion Interfaces). Refer to Figure 746-2. Use the following procedures for changing the configuration on the appropriate SEPI(s):

T3 Card Configuration

DLP-753

155 CRS Card Configuration

DLP-752

622 CRS Card Configuration

DLP-797

6.Select the Next>> button to continue with the procedure after reconfiguring the SEPIs.

7.Step 4 of the Task Overview indicates that the system is updating the database. This will only take a few seconds to complete. Once finished, the user is prompted to physically disconnect the expansion shelf from the RNE. Refer to Figure 746-4. Pull the cards out of the shelves and remove the fibers if necessary.

Danger: Do not look into the ends of optical fibers. Exposure to invisible LASER radiation may cause serious retinal damage or even blindness. Verify the optical source is disabled through the use of an optical power meter before handling optical fibers.

Stop! You have completed this procedure.

Page 2-218

2000, ADC Telecommunications, Inc.

Page 238