ADC Release 3.1 user manual Alarm Identifications

Models: Release 3.1

1 489
Download 489 pages 5.8 Kb
Page 466
Image 466

1152700Issue 1 February 2001 Section 2 Operations and Maintenance

TAP-100

Page 3 of 23

Table 4-1. Alarm Identifications, continued

ALARM MESSAGE

SEVERITY

IMPACT

 

DESCRIPTION

 

SUGGESTED COURSE OF ACTION

 

 

 

 

 

 

 

 

Alarm

Indication

Signal Line

AIS-L

Alarm

Indication

Signal Path

AIS-P

Burst

Errored

Second

Threshold

Crossing

Alert

BESTca

Card

Inserted

CardInserte d

Minor

Minor

Information al Alert

Information al Alert

Service

Affecting

Service

Affecting

Not Service Affecting

Maintenance

The line level has an alarm indication signal present. TX AIS generally informs the user that the card has lost its input at the AIC, RX AIS informs the user that the card is receiving AIS from the far end which has lost its input at the AIC.

Generally informs the user that the transmitting LTE has lost its input at the AIC. TX AIS generally informs the user that the card has lost its input at the AIC, RX AIS informs the user that the card is receiving AIS from the far end which has lost its input at the AIC.

DSX1 alarm: A burst of errored seconds at the T1 level has exceeded the threshold setting.

Card is inserted into backplane slot. Informs user that a card is physically present.

Check input source/ connections and facility status. AIS is detected when the line has trouble.

Check input source/connections and facility status.

Check input source signal level and pulse mask, increase threshold level if needed.

No action necessary.

Card Removed

CardRemov ed

Card Type Mismatch

CardTypeM ismatch

Minor

Information al Alert

Maintenance

Installation Error

Informs user that the card has been removed from the backplane.

Informs user that the inserted card type is different from previous card type for that slot. A different card type may have been inserted into the wrong slot.

Locate card and reinstall if necessary, otherwise, delete the card and facility from database. Refer to NTP-006 section B.

Verify slot configuration and replace card with valid type. If changing configuration, delete previous configuration data for that slot and change out the EIM at the rear of the shelf if necessary.

(continued)

Page 2-422

© 2000, ADC Telecommunications, Inc.

Page 466
Image 466
ADC Release 3.1 user manual Alarm Identifications