1152700 Issue 1 February 2001 Section 2 Operation and Maintenance

DLP-752

Page 4of 4

Table 752-2. ATM Interface Configuration Options, continued

SELECTION

Recording Interface

ID

UNI/ NNI Select

CAC Formula

Traffic Policing

Cell Scrambling

Subscription Rate

Max Active

VPI/VCI Bits

Max number of VPCs

Max number of VCCs

DEFAULT

All 0s

UNI

PCR

Enable

True

100

0

4096

0

OPTIONS

Numeric

UNI

NNI

PCR

SCR

Enable

Disable

True or False

PCR: 100 to 1000

SCR: 1 to 100

0 to 12

0-4096

0-8192

DEFINITIONS

Identifies the site card and port location for customer billing capabilities, (allows assignment of a customer ID for each port.) The code is limited to 15 numeric characters.

Specifies interface type as User to Network Interface or Network to Network Interface.

Specifies Peak Cell Rate or Sustained Cell Rate for Connection Admission Control calculations.

User sets whether traffic will be policed for Quality Of Service (QOS).

User sets whether traffic will be scrambled.

User sets depending on traffic contract.

Sets maximum number of bits allowed to select virtual channel from.

Sets maximum number of virtual path circuits that may be assigned on this port.

Sets maximum number of virtual channel circuits that may be assigned on this port.

 

Cellworx Vision: ATM Interface

 

 

X

 

 

 

 

 

Node Name:

Cellworx1

 

 

Slot Number:

9

 

Node Id:

1

 

 

 

 

Card :

 

155 SM CRS

Location:

5th Street

 

 

Port Number:

1

 

Interface Name:

 

 

 

Slot9_Port1 OC3SM

 

 

Loopback Location Code:

 

1111111111111111

 

 

Recording Interface ID:

 

0000000000000000

 

 

Provisioned Endpoints:

 

 

 

 

 

 

 

Number of VPCs:

0

 

 

 

 

 

 

 

Number of VCCs:

0

 

 

 

 

 

 

 

Interface Type:

 

CAC Formula:

 

 

 

 

 

 

UNI

 

 

 

PCR Based

 

Policing

 

 

 

NNI

 

 

 

SCR Based

 

Cell Scrambling

 

Over Subscription Rate (%):

 

 

100

(100-10

VP/VC Allocation:

 

 

 

 

 

 

 

 

 

0

Max Active VPI Bits:

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

0

1

2

3

4

5

6

7

8

9

10

1

Max Active VCI Bits:

 

 

 

 

 

 

 

0

 

 

 

 

 

 

 

 

 

 

 

0

 

 

 

 

 

 

 

 

 

 

 

Max Number of VPCs:

 

4096

 

(1-128)

 

Max Number of VCCs:

 

 

0

 

(0-8192)

 

Error Log:

 

 

 

 

 

 

 

 

 

 

Apply

Card View

Refresh

Close

13429-B

Figure 752-2. 155 SM/MM CRS ATM Port Interface Configuration Screen

Page 2-240

© 2000, ADC Telecommunications, Inc.

Page 260
Image 260
ADC Release 3.1 user manual 4of ATM Interface Configuration Options, SM/MM CRS ATM Port Interface Configuration Screen