1152700 Issue 1 February 2001 Operation and Maintenance

DLP-788

Page 2 of 3

Table 788-1. Display FT1 FRS Card Status Definitions

ITEM

Operational State

Availability State

Protection Status

STATUS

Up

Down

Unknown

Available

In Test

Failed

Power Off

Not Installed

Off Line

Dependency

Unknown

Not

Protected

DEFINITION

CARD LEVEL

Card is functioning properly.

Card is not functioning properly, is in reset mode, or failed. Check Admin state.

The shelf controller does not currently know the operational status.

Card is ready for processing commands.

Card is currently processing test signals.

Card has failed operation and system has placed it out of service.

No power to the card.

Card is not currently installed in selected slot of the shelf.

Card is installed and provisioned but currently off line.

Card is supplying timing reference, traffic, or other data to the system.

The system processor does not currently know the availability state.

Not Protected

ACTION

No action required.

Verify card is installed, check for failure indications, or provision card for service per DLP-785.

Wait a few seconds for operations to complete and update the screen.

No action required.

Wait a few seconds for screen to update.

Card may be performing a reset, or the bus may be busy.

Check power source, replace card if source is good per DLP-777.

If required, install card in selected slot per DLP-777 and provision per DLP- 785.

If required, set module on line per DLP- 785.

Wait for processor to update current status, may need to perform a manual reset of SC per DLP-773.

Protection operation on FRS cards is not available with release 3.1 software.

(continued)