1152700 • Issue 1 • February 2001 • Operation and Maintenance
DLP-785
Page 5 of 7
Table 785-2. FT1 FRS Configuration Options
SELECTION
Card and Port
Administrative
State
Congestion
Threshold
Ring Selection
Low Ingress/Egress
Buffer Congestion
Onset/Abatement
High
Ingress/Egress
Buffer Congestion
Onset/Abatement
Transmit Timing Source
Channel Bit Rate
Facility Data Link
Line Build Out
Line Coding
Line Type
Circuit Identifier
DEFAULT | OPTIONS |
Unlocked | Unlocked |
| Locked |
|
|
80 | |
|
|
Auto | Auto |
| Ring 16 |
| Ring 17 |
<default> | Variable |
|
|
<default> | Variable |
|
|
Local | Received |
| Local |
|
|
6464
56
None |
| |
| FDL | |
| None | |
|
| |
0 – 133 ft | ||
| 133 | – 266 ft |
| 266 | – 399ft |
| 399 | – 533ft |
| 533 | – 655ft |
B8ZS | Non |
|
| configurable | |
Extended | Non |
|
Superframe | configurable | |
<default> | Up to 20 | |
| alphanumeric | |
| characters. |
DEFINITIONS
Enables or disables card/port for service, respectively.
Percentage of ingress/egress buffer capacity that will cause a congestion threshold notification.
Card will automatically select traffic from the ring direction with the best signal.
Card will receive traffic from Ring 16 direction. Card will receive traffic from Ring 17 direction.
This will cause the FECN/BECN in the frame relay header to be set or cleared. Abatement is always ten percent less than onset.
Exceeding threshold causes frames with DE field equal to 1 to be discarded. Frame discarding stops upon reaching abatement level. Abatement is always ten percent less than onset.
Incoming clock pulse used for outgoing signal.
Clock pulse supplied by the SC cards used for outgoing signal.
Sets the Kilobits Per Second (Kbps) data rate for the channels provisioned on the port.
A
Sets the signal strength according to the distance in feet that the Cellworx STN is from the T1 interfacing equipment.
Bit 8 Zero Substitution
Extended Superframe
User defined. Usually describes the traffic, customer, and/or channel number.
Page