ADC Release 3.1 user manual RIC Card Status Definitions, Los Lof, Ais Rdi

Models: Release 3.1

1 489
Download 489 pages 5.8 Kb
Page 287
Image 287

1152700 Issue 1 February 2001 Section 2 Operation and Maintenance

Page 2 of 3

ITEM

CARD

DLP-759

Table 759-1. 622 RIC Card Status Definitions

 

STATUS

 

DEFINITION

 

ACTION

 

 

 

 

 

 

Operational State

Availability State

PORT

Section

Status

Line Status

Up

Down

Unknown

Available

In Test

Failed

PowerOff

Not Installed

Offline

Dependency

Unknown

No Alarm

LOS

LOF

No Alarm

AIS

RDI

Card is functioning properly.

Card is not functioning properly, is in reset mode, or failed. Check Admin state.

The system processor does not currently know the operational status.

Card is ready for processing commands.

Card is currently processing test signals.

Card has failed operation and system has placed it out of service.

No power to the card.

Card is not installed.

Card is installed and provisioned but currently off line.

Card is supplying timing reference, traffic, or other data to the system.

The system processor does not currently know the availability status.

No errors between local and next node.

Loss Of Signal (cannot locate section data)

Loss Of Frame (cannot locate frame bit of section data)

Receiving good input signal

Alarm Indication Signal, inserted all 1s or blue signal at originating node.

Remote Defect Indicator. Far end sending indication that it is receiving a defective signal.

No action required.

Verify card is installed,

check for failure indications or provision card for service per DLP- 751.

Wait a few seconds for system to complete its operations and then refresh the screen.

No action required.

Wait a few seconds for screen to update.

Card may be performing a reset, or the bus may be busy.

Check power source. Replace card if source is good per DLP-777.

If required, install card in selected slot per DLP-777 and provision per DLP-751.

If required, set module on line per DLP-751.

Perform a soft switch over (manual) per DLP-771 to release card dependency if removing.

Wait for processor to update current status, may need to perform a manual reset of SC per DLP-773.

No action required.

Check connectors, fiber, and transmitter at other end.

Check signal type, and power level of received signal.

No action required.

Check signal status at traversing nodes, and low speed signal input at transmitting node.

Check local transmitting end signal for defects.

(continued)

Page 2-267

© 2000, ADC Telecommunications, Inc.

Page 287
Image 287
ADC Release 3.1 user manual RIC Card Status Definitions, Los Lof, Ais Rdi