1152700 Issue 1 February 2001 Section 2 Operation and Maintenance

DLP-750

Page 1 of 2

SET SHELF HOUSEKEEPING ALARM CONFIGURATION

Summary: This procedure details the steps required to configure the housekeeping alarm messages that will be displayed when an input is triggered via an external source.

1.From the shelf level GUI Chassis View window, select the Fault pull down menu using the mouse to click on it, or by entering “Alt+A” on the keyboard. Refer to Figure 750-1.

2.Select the Configure Housekeeping Alarms option using the down arrow keys to highlight it and hitting “Enter” or “Return”, or by entering an “Alt+A” on the keyboard.

3.The Housekeeping Alarms shelf level GUI display appears as shown in Figure 750-2. The State column indicates the current state of that alarm input. A green square indicates no alarm is present, while the Red square indicates an alarm condition is active on that input.

4.Enter in an alarm description for each of the eight alarm interfaces according to the type of equipment hardwired to the SC EIM card. Refer to the label located inside the front door panel if necessary. This label should have been filled out by the installer during installation. Refer to List of related Publications in the preface of this manual for installation procedures.

5.Select the Apply button at the bottom of the window to send the new configuration data to the database.

6.Select the Close button at the bottom of the window to return to the shelf level GUI Chassis View screen.

Stop! You have completed this procedure.

SELECT THE FAULT PULLDOWN MENU USING LEFT MOUSE BUTTON OR BY PRESSING THE ALT+A KEYS SIMULTANEOUSLY.

 

Cellworx Vision: Chassis View, Network Element 2

 

 

X

 

 

 

 

 

 

 

File

Configuration

Fault

 

Security

 

 

 

 

 

 

 

 

 

Configure Housekeeping Alarms

 

 

 

S

N

Execute Alarm Cut-Off

RE RRE

6

6

S

T

T

T

T

T

C

M

3 M

1

3

3 1 1

2

2

C

 

I

T

U

M

 

 

M

M

2

2

 

 

C

M

X

u

C

C

u

u

 

 

 

 

 

U

 

l

R

R

l

l

R

R

 

 

 

X

E

t

S

S

t

t

i

i

 

 

 

 

X

i

 

 

i

i

n

n

 

13473-C

Figure 750-1. Shelf Level GUI Fault Pull Down Menu

Page 2-232

© 2000, ADC Telecommunications, Inc.

Page 252
Image 252
ADC Release 3.1 user manual SET Shelf Housekeeping Alarm Configuration, Shelf Level GUI Fault Pull Down Menu