7. Launch the Cellworx Vision Graphical User Interface (GUI).  | 
8.After the GUI boots up, it will prompt the user to synchronize the database. Choose the active NMIC’s database as the correct database to synchronize.
9.  | Perform a discovery for a new Cellworx STN ring network.  | |
10.  | Set the Date and Time on the NMIC.  | |
11.  | Set the System Identifier for each node.  | |
12.  | After all nodes are successfully discovered, configure them  | 
  | 
  | before adding any expansion shelves. Configuration may include  | 
  | 
  | timing configuration, locking ports to remove LOS alarms,  | 
  | 
  | configuring the max VC bits to greater than zero to allow VC  | 
  | 
  | connections for each port, etc.  | |
13.  | Refresh the GUI screen so the nodes will display the new names.  | 
14.Perform acceptance tests on the new nodes per local
  | requirements.  | |
15.  | Add expansion shelves to the ring nodes if equipped.  | |
16.  | Save the NMIC database.  | 
Stop! You have completed this procedure.