ADC Release 3.1 user manual RIC Configuration Options, Sonet

Models: Release 3.1

1 489
Download 489 pages 5.8 Kb
Page 279
Image 279

1152700 Issue 1 February 2001 Section 2 Operation and Maintenance

DLP-756

Page 3 of 3

Table 756-1. 2488 RIC Configuration Options, continued

SELECTION

DEFAULT

Signal

5

Degrade BER

 

Threshold

 

Medium Type

SONET

 

 

Loopback

None

towards

 

 

 

OPTIONS

5 through 9

SONET

SDH

None

Terminal

Facility

DEFINITION

Defines the number of bit errors the port can incur before a signal degrade occurs and generates an alarm message and probably protection switch.

Not configurable on RIC. This is determined by the dip-switch on the SC EIM, which sets the shelf type.

No loopback activated on this card.

Sends cells back to the cellbus and back out to the ring. No changes are made to the path layer data.

Loops the incoming signal back to the CPE and generates AIS to the cellbus.

Line Coding

Line Type

Transmit Path Trace

NRZ

Card Dependant

(example)

NE1_Slot17_ Port1 (OC48)

sonetOther

sonetShortSingle Mode

sonetLongSingle Mode

sonetMultiMode

Not configurable by user.

Not configurable by user, card type dependant on card inserted.

Card position dependent. This is assigned by the system according to the NE and slot it is equipped in.

Page 2-259

© 2000, ADC Telecommunications, Inc.

Page 279
Image 279
ADC Release 3.1 user manual RIC Configuration Options, Sonet