1152700 • Issue 1 • February 2001 • Section 2 Operation and Maintenance
Page 3 of 3
Table 756-1. 2488 RIC Configuration Options, continued
SELECTION | DEFAULT |
Signal | 5 |
Degrade BER |
|
Threshold |
|
Medium Type | SONET |
|
|
Loopback | None |
towards |
|
|
|
OPTIONS
5 through 9
SONET
SDH
None
Terminal
Facility
DEFINITION
Defines the number of bit errors the port can incur before a signal degrade occurs and generates an alarm message and probably protection switch.
Not configurable on RIC. This is determined by the
No loopback activated on this card.
Sends cells back to the cellbus and back out to the ring. No changes are made to the path layer data.
Loops the incoming signal back to the CPE and generates AIS to the cellbus.
Line Coding
Line Type
Transmit Path Trace
NRZ
Card Dependant
(example)
NE1_Slot17_ Port1 (OC48)
sonetOther
sonetShortSingle Mode
sonetLongSingle Mode
sonetMultiMode
Not configurable by user.
Not configurable by user, card type dependant on card inserted.
Card position dependent. This is assigned by the system according to the NE and slot it is equipped in.
Page
© 2000, ADC Telecommunications, Inc.