Page 1 of 2
TURN UP A NEW CELLWORX STN RING NETWORK
Summary: This procedure covers initial ring network
| Note: If adding a new node to an existing ring network, go to |
|
| Note: If adding a node to an | |
| Multiplexer (SAM) to form a ring, go to |
|
| Note: If adding expansion shelves to existing nodes, go to |
|
1. | Verify NMICs are inserted. |
|
2. | Verify all shelf controllers and AICs are installed and nodes are |
|
| powered on. If not powered, perform power on procedures. | |
3. | Verify that the GNE node, ring nodes, expansion nodes, and/or |
|
| SAM/DSLAM nodes are properly identified by the thumbwheel |
|
| switch settings on the SC terminating EIM (TEIM) at the rear of |
|
| the shelf in slot 18. Refer to the Phase 3.1 Cellworx Installation |
|
| Manual listed in the preface of this document. | 1152693 |
| Note: If the ID switches are reset then the SC must be hard reset using the Reset buttons | |
| under the front hinged panel. |
|
4. | All RIC cards should have fibers connected with one ring in a |
|
| clockwise direction, and the other in a |
|
| direction. If fibers are not installed, install per local practices |
|
| and connect to optical cards. | |
5. | Obtain the IP address of the NMIC. If the IP address is not set, |
|
| connect a VT100 Terminal to the NMIC RS232 port and set the |
|
| IP address for the GNE. Call the Customer Service number at |
|
| the back of this manual if the address has already been set. |
6.Connect an Ethernet cable to the NMIC Ethernet port on the
NMIC EIM (Electrical Interface Module) at the rear of the shelf. |
Note: The NMIC will boot and download slot 1 shelf controllers in each ring NE. The slot one SC in each node then downloads to each slot 18 SC.
Page
© 2000, ADC Telecommunications, Inc.