Page 1 of 2
TURN UP A NEW CELLWORX STN RING NETWORK
Summary: This procedure covers initial ring network 
  | Note: If adding a new node to an existing ring network, go to   | 
  | 
  | Note: If adding a node to an   | |
  | Multiplexer (SAM) to form a ring, go to   | 
  | 
  | Note: If adding expansion shelves to existing nodes, go to   | 
  | 
1.  | Verify NMICs are inserted.  | 
  | 
2.  | Verify all shelf controllers and AICs are installed and nodes are  | 
  | 
  | powered on. If not powered, perform power on procedures.  | |
3.  | Verify that the GNE node, ring nodes, expansion nodes, and/or  | 
  | 
  | SAM/DSLAM nodes are properly identified by the thumbwheel  | 
  | 
  | switch settings on the SC terminating EIM (TEIM) at the rear of  | 
  | 
  | the shelf in slot 18. Refer to the Phase 3.1 Cellworx Installation  | 
  | 
  | Manual listed in the preface of this document.  | 1152693  | 
  | Note: If the ID switches are reset then the SC must be hard reset using the Reset buttons  | |
  | under the front hinged panel.  | 
  | 
4.  | All RIC cards should have fibers connected with one ring in a  | 
  | 
  | clockwise direction, and the other in a   | 
  | 
  | direction. If fibers are not installed, install per local practices  | 
  | 
  | and connect to optical cards.  | |
5.  | Obtain the IP address of the NMIC. If the IP address is not set,  | 
  | 
  | connect a VT100 Terminal to the NMIC RS232 port and set the  | 
  | 
  | IP address for the GNE. Call the Customer Service number at  | 
  | 
  | the back of this manual if the address has already been set.  | |
6.Connect an Ethernet cable to the NMIC Ethernet port on the
NMIC EIM (Electrical Interface Module) at the rear of the shelf.  | 
Note: The NMIC will boot and download slot 1 shelf controllers in each ring NE. The slot one SC in each node then downloads to each slot 18 SC.
Page 
© 2000, ADC Telecommunications, Inc.