1152700 Issue 1 February 2001 Section 2 Operation and Maintenance

DLP-757

Page 2 of 3

Table 757-1. Shelf Controller Status Definitions

ITEM

Operational

Status

Availability State

Protection State

STATUS

Up

Down

Unknown

Available

Unavailable

In Test

Failed

Power off

Not Installed

Offline Dependency

Unknown

Enabled

Not Protected

DEFINITION

Card is installed and functioning properly.

Card is not functioning properly, is in reset mode, or failed.

The system processor does not currently know the operational

Card is ready for processing commands.

Card is in standby mode or busy processing commands.

Card is currently in a test mode.

Card requires operator intervention.

No power is applied to card.

Card is not physically installed into the backplane.

Card is installed but not in service.

Card is supplying timing reference, traffic, or other data to the system.

The system processor does not currently know the availability status.

Protection operation is supported.

No protection card is available.

ACTION

No action required.

Verify card is installed, check for failure indications and alarms.

Wait a few seconds for system to complete its operations and then update the screen.

No action required.

Wait a few moments and recheck status.

Wait a few moments and recheck status.

On site replacement of failed SC card. Refer to DLP-777.

Check power source. Replace card if necessary per DLP-777.

Try other SC card slot, install missing card if required. Per DLP-777.

No action required.

Perform a soft switch over (manual) per DLP-771 to release card dependency if removing.

Wait for processor to update current status, may need to perform a card reset per DLP- 773.

No action required.

Add or replace the inactive SC card per DLP-777.