1152700 • Issue 1 • February 2001 • Section 2 Operation and Maintenance
ITEM
Page 2 of 3
Table 793-1. T3 CES Card Status Definitions
| STATUS |
| DEFINITION |
| ACTION |
|
|
|
|
|
|
|
|
Operational
State
Availability State
Protection State
Up
Down
Unknown
Available
In Test
Failed
Power Off
Not Installed
Off Line
Dependency
Unknown
Not
Protected
Enabled
Manual switch
Forced
Switch
Lockout
Unknown
Card is functioning properly.
Card is not functioning properly, is in reset mode, or failed. Check Admin state.
The shelf controller does not currently know the operational status.
Card is ready for processing commands.
Card is currently processing test signals.
Card has failed operation and system has placed it out of service.
No power to the card.
Card is not currently installed in selected slot of the shelf.
Card is installed and provisioned but currently off line.
Card is supplying timing reference, traffic, or other data to the system.
The system processor does not currently know the availability status.
Not Protected
Protection is available for selected card but is not active.
User has manually switched the card to protection.
User has forced card to protection.
Card cannot switch to protection. It has been locked out by command or switch count.
Protection status information is not available to the shelf controller.
No action required.
Verify card is installed, check for failure indications, or provision card for service per DLP- 792.
Wait a few seconds for operations to complete and update the screen.
No action required.
Wait a few seconds for screen to update.
Card may be performing a reset, or the bus may be busy.
Check power source, replace card if source is good.
If required, install card in selected slot per
If required, set module on line per DLP- 792.
Perform a soft switch over (manual) per
Wait for processor to update current status, may need to perform a manual reset of SC per
If equipped, set up a protection group and provision card for protection per
No action necessary.
If required, switch the card back per
If required, release forced switch per
If required, release manual
Wait a few minutes and update screen. May need to reset SC, refer to
(continued)
Page
© 2000, ADC Telecommunications, Inc.