ADC Release 3.1 user manual T3 CES Card Status Definitions

Models: Release 3.1

1 489
Download 489 pages 5.8 Kb
Page 438
Image 438

1152700 Issue 1 February 2001 Section 2 Operation and Maintenance

ITEM

DLP-793

Page 2 of 3

Table 793-1. T3 CES Card Status Definitions

 

STATUS

 

DEFINITION

 

ACTION

 

 

 

 

 

 

 

 

Operational

State

Availability State

Protection State

Up

Down

Unknown

Available

In Test

Failed

Power Off

Not Installed

Off Line

Dependency

Unknown

Not

Protected

Enabled

Manual switch

Forced

Switch

Lockout

Unknown

Card is functioning properly.

Card is not functioning properly, is in reset mode, or failed. Check Admin state.

The shelf controller does not currently know the operational status.

Card is ready for processing commands.

Card is currently processing test signals.

Card has failed operation and system has placed it out of service.

No power to the card.

Card is not currently installed in selected slot of the shelf.

Card is installed and provisioned but currently off line.

Card is supplying timing reference, traffic, or other data to the system.

The system processor does not currently know the availability status.

Not Protected

Protection is available for selected card but is not active.

User has manually switched the card to protection.

User has forced card to protection.

Card cannot switch to protection. It has been locked out by command or switch count.

Protection status information is not available to the shelf controller.

No action required.

Verify card is installed, check for failure indications, or provision card for service per DLP- 792.

Wait a few seconds for operations to complete and update the screen.

No action required.

Wait a few seconds for screen to update.

Card may be performing a reset, or the bus may be busy.

Check power source, replace card if source is good.

If required, install card in selected slot per DLP-777 and provision per DLP- 792.

If required, set module on line per DLP- 792.

Perform a soft switch over (manual) per DLP-771 to release card dependency if removing.

Wait for processor to update current status, may need to perform a manual reset of SC per DLP-773.

If equipped, set up a protection group and provision card for protection per DLP-765.

No action necessary.

If required, switch the card back per DLP-771.

If required, release forced switch per DLP-771.

If required, release manual lock-out per DLP-771.

Wait a few minutes and update screen. May need to reset SC, refer to DLP-773.