ADC Release 3.1 user manual Sefs SES, Sonet PM Values

Models: Release 3.1

1 489
Download 489 pages 5.8 Kb
Page 165
Image 165

1152700 Issue 1 February 2001 Section 2 Operation and Maintenance

DLP-726

Page 3 of 4

Cellworx Vision: Performance Monitoring Data NE 2

 

 

X

 

 

 

 

 

 

Only non-zero selected intervals are displayed.

 

 

 

 

SONET Path SONET Line SONET Section

Card Type

155 MM CRS

Slot-Port

S12-P2

Interval

00:00 - 00:15

Suspect Supp

0

0

 

 

ESs

0

SESs

0

CVs

0

UASs

900

FE ESs

0

FE SESs

FE CVs

0

0

 

 

Refresh

Refresh All

Reset Selected

Clear Selected

Configure Thresholds

Close

13556-B

Figure 726-2. Performance Monitoring Data – SONET Port Window

Cellworx Vision: PM Threshold Configuration SONET Path Layer

 

 

 

 

X

Card Type

Slot-Port

ESs

SESs

CVs

UASs

FE ESs

FE SESs

 

FE CVs

FE UAS

622 Ring

S17-P1

60

3

75

10

60

3

0

 

0

 

 

 

Apply

Close

13552-B

Figure 726-3. 622 Ring Card SONET Path PM Threshold Configuration Screen

MONITOR

TYPE

CV

ES

SEFS

SES

MAX 15-MIN THRESHOLD

16383

900

900

900

Table 726-1. SONET PM Values

COMMENTS

SECTION

Code Violation, a count of Bit Interleaved Parity (BIP) errors detected at the Section layer using the B1 byte in the incoming SONET signal

Errored Seconds, number of seconds in which at least one Section layer Bit Interleaved Parity (BIP), Loss Of Signal (LOS), or Severely Errored Frame (SEF) was detected

Severely Errored Frame Seconds, a count of seconds that four consecutive incoming section frames are errored

Severely Errored Seconds, a count of seconds in which a set number of Section BIP errors, LOS, or SEF were detected

(continued)

Page 2-145

2000, ADC Telecommunications, Inc.

Page 165
Image 165
ADC Release 3.1 user manual Sefs SES, Sonet PM Values