1152700 • Issue 1 • February 2001 • Section 2 Operation and Maintenance
DLP-726
Page 3 of 4
Cellworx Vision: Performance Monitoring Data NE 2 |
|
| X |
|
|
|
|
|
|
Only |
|
|
|
|
SONET Path SONET Line SONET Section
Card Type
155 MM CRS
Interval
00:00 - 00:15
Suspect Supp
0 | 0 |
|
|
ESs
0
SESs
0
CVs
0
UASs
900
FE ESs
0
FE SESs | FE CVs |
0 | 0 |
|
|
Refresh | Refresh All |
Reset Selected
Clear Selected
Configure Thresholds
Close
Figure 726-2. Performance Monitoring Data – SONET Port Window
Cellworx Vision: PM Threshold Configuration SONET Path Layer |
|
|
|
| X | |||||
Card Type | ESs | SESs | CVs | UASs | FE ESs | FE SESs |
| FE CVs | FE UAS | |
622 Ring | 60 | 3 | 75 | 10 | 60 | 3 | 0 |
| 0 | |
|
|
|
Apply |
Close |
Figure 726-3. 622 Ring Card SONET Path PM Threshold Configuration Screen
MONITOR
TYPE
CV
ES
SEFS
SES
MAX
16383
900
900
900
Table 726-1. SONET PM Values
COMMENTS
SECTION
Code Violation, a count of Bit Interleaved Parity (BIP) errors detected at the Section layer using the B1 byte in the incoming SONET signal
Errored Seconds, number of seconds in which at least one Section layer Bit Interleaved Parity (BIP), Loss Of Signal (LOS), or Severely Errored Frame (SEF) was detected
Severely Errored Frame Seconds, a count of seconds that four consecutive incoming section frames are errored
Severely Errored Seconds, a count of seconds in which a set number of Section BIP errors, LOS, or SEF were detected
(continued)
Page
2000, ADC Telecommunications, Inc.