1152700Issue 1 February 2001 Section 2 Operations and Maintenance

TAP-100

Page 10 of 23

Table 4-1. Alarm Identifications, continued

ALARM

SEVERITY

MESSAGE

 

 

IMPACT

DESCRIPTION

SUGGESTED COURSE OF ACTION

 

 

 

 

Far End Loss

Critical

Of Signal

 

LOS-FE

 

 

 

Far End

Minor –

Protection

currently

Line Failure

an

FarEndProtLi

informati

onal

neFailed

alert.

 

Fifteen

Informati

Minute

onal

Interval,

Alert

Errored

 

Seconds

 

Threshold

 

Crossing

 

Alert

 

EESCMajor1

 

5minTca

 

Housekeepin

Minor

g AlarmX

 

HouseKeepin

 

gAlarm”X”

 

 

 

Service

Outage

Service Affecting

Service Degradation

Not Service Affecting

No input signal is being provided at the far end.

Far end protection line is no longer available.

Exceeded errored seconds have crossed a user definable major or minor threshold crossing alert for a 15 minute period causing an alarm report.

X = input numbers 1 to 8. User defined housekeeping input on port listed has received an alarm.

Check input connections at the far end and transmitting equipment into the far end low speed facility.

Check fiber facilities and connections to protect card. Verify Protection EIMs (PEIM) are installed. Check facility status and alarm reports.

Retrieve PM data to determine problem cards/ports. Check inputs and signal levels. Replace problem cards if necessary. See Section 6 of this manual for warranty and return authorization information.

Refer to label inside front door panel for correlating input type. Troubleshoot accordingly..

Ingress

Congestion

Threshold

Crossing

Alert

IngressConge stTca

Line Code

Violations

Threshold

Crossing

Alert

LCVTca

Informati onal Alert

Informati onal Alert

Service Degradation

Service Degradation

Ingress congestion threshold crossing alert. Cells congested on the ingress of reported port have crossed a user definable threshold level.

Line code violations have exceeded the user definable threshold level causing a Threshold Crossing Alert (Tca).

Review traffic contracts and modify threshold level if needed. Monitor for future congestion alarms. Cells tagged for discard become susceptible to termination.

Check input from Customer premise Equipment (CPE), signal level and pulse mask.