1152700 Issue 1 February 2001 Section 2 Operation and Maintenance

DLP-726

Page 4 of 4

MONITOR TYPE

CV-L16383

CV-LFE 16383

ES-L900

ES-LFE 900

SES-L 900

SES-LFE 900

UAS-L 900

UAS-LFE 900

CV-P16383

CV-PFE 16383

ES-P900

ES-PFE 900

SES-P 900

SES-PFE 900

UAS-P 900

UAS-PFE 900

Table 726-1. SONET Layer PM Values, continued

COMMENTS

LINE

Line Code Violation, count of BIP errors detected at the Section layer using the B2 byte in the incoming SONET signal

Far-end Line Code Violation, a count of BIP errors detected at the far end LTE and reported back to the near end LTE using the Remote Error Indicator (REI) in the Line overhead

Line Errored Seconds, number of seconds in which at least one Line layer BIP, or an AIS condition was detected

Far-end Line Errored Seconds, count of the seconds in which at least one Line BIP was detected by the far end LTE or an RDI-L defect was present

Line Severely Errored Seconds, a count of seconds in which a set number of Line layer BIP errors, or an AIS condition were detected

Far-end Line Severely Errored Seconds, a count of seconds in which a set number of Line layer BIP errors, or AIS were detected by the far end LTE

Line Unavailable Seconds, a count of seconds in which the Line was considered unavailable

Far-end Line Unavailable Seconds, a count of seconds in which the Line was considered unavailable, reported by the far end LTE to the near end LTE using the RDI in the Line overhead

PATH

Code Violation, a count of BIP errors detected at the Path layer using the B3 byte of the incoming SONET signal

Far-end Path Code Violation, a count of BIP errors detected at the far end LTE and reported back to the near end LTE using the Remote Error Indicator (REI) in the Path overhead

Path Errored Seconds, number of seconds in which at least one Path layer BIP, Alarm Indication Signal (AIS), or Loss Of Pointer (LOP) condition was detected

Far-end Path Errored Seconds, count of the seconds in which at least one Path layer BIP was detected by the far end LTE or an RDI-P defect was present

Path Severely Errored Seconds, a count of seconds in which a set number of Path BIP errors, AIS, or LOP were detected

Far-end Path Severely Errored Seconds, a count of seconds in which a set number of Path layer BIP errors, AIS, or LOP were detected by the far end LTE and reported back to the near end LTE using the RDI-P bit in the Path overhead

Line Unavailable Seconds, a count of seconds in which the Line was considered unavailable

Far-end Path Unavailable Seconds, a count of seconds in which the Path was considered unavailable, reported by the far end LTE to the near end LTE using the RDI in the Path overhead

Page 2-146

2000, ADC Telecommunications, Inc.

Page 166
Image 166
ADC Release 3.1 user manual Ses-Lfe, Uas-Lfe, Ses-Pfe, Uas-Pfe, Sonet Layer PM Values