Manuals
/
ADC
/
Computer Equipment
/
Network Card
ADC
Release 3.1
user manual
Models:
Release 3.1
1
2
489
489
Download
489 pages
5.8 Kb
1
2
3
4
5
6
7
8
Troubleshooting
Install
Error codes
Tops Document Flow Chart
Displaying Status and Alarms
Cellworx Vision Error
Login
Administrative Tasks
Warranty
Card Configurations
Page 2
Image 2
Page 1
Page 3
Page 2
Image 2
Page 1
Page 3
Contents
Cellworx STN
Page
Issue February Rev a
Trademark Information
Copyright
Revision History
Disclaimer of Liability
Table of Contents
Section Operation and Maintenance
Indexed Task List
Find Your Job in the List Below Then Go To
Find Your Job in the List Below
Section
General Information
About this Manual
Trademark Information
General Safety Precautions
FCC Compliance Statement
Class a
Standards
ITU
List of Acronyms and Abbreviations
LAN
UBR
Section Introduction
General
User Interfaces
Cellworx STN Shelf
Nmic RS232 Interface
Nmic Serial Equipment Port
Cellworx STN System Software
GUI Screen Icon Definitions
Example of Primary Node with Secondary Expansions
Cellworx Shelf Level GUI Screen
GUI Menu Structure and Utilization
Cellworx STN GUI Display sample
10. Cellworx Vision Pull Down Menus and Pop-up Window Trees
12. GUI Tool Bar Icon Definitions
Terminal Keyboard Functions
Remote Management Capabilities
14. Remote X-Terminal Operations
Real-time Alarm and Trap Screens
Using a TOP Document
General
Tops Document Flow Chart
Alphabetical Task Index List
ADD/DELETE GUI Users or Change GUI User Level Security
DLP-771
DLP-752
Indexed Task List
Delete a Cellworx STN Node RNE or EPS
Turn UP a NEW Cellworx STN Ring Network
Stop! You have completed this procedure
ADD a Cellworx STN Node to AN IN-SERVICE Ring Network
NTP-004
Turn UP Provision Cellworx STN Expansion Shelves
NTP-005
Provision Node Parameters
Shelf Parameters
Shelf Level GUI Display
Card Configurations
Performance Monitoring Parameters
Cellworx Vision Performance Pull Down Menu
Stop! You have completed this procedure
Displaying Status and Alarms
Displaying Alarms
Shelf Level GUI Screen example
Stop! You have completed this procedure
Retrieve Performance Monitoring Statistics
Cellworx Vision Performance Monitoring Selection Window
Adding Services to a Cellworx STN Node
Delete a Ring Node from AN IN-SERVICE Ring System
Delete a Cellworx STN Node
Conduct Acceptance Tests on a Cellworx STN Node
Perform Routine or NON-ROUTINE Maintenance
Graphical User Interface Procedures
Creating Connections
Network Layout View
Icon Alarm Indications
Monitoring the Network
Directives
NTP-014 Adding Services
Help Line
Administrative Tasks
NTP-015
Cellworx Ugrade Procedures
Software Upgrade
Ring Upgrade
Power UP a Cellworx STN Node
Cellworx STN Component Identification
Fiber Routing
Connect Fibers to Optical Cards
Optical Connector Identification
Routing Fiber Across the Fiber Management Panel
Fiber Connection
Cleaning
Connectors/Terminators
Adapters
Mating
Attenuators
Stop! You have completed this procedure
Disengaging the Optical Module
Fiber Connections on a Cellworx 622 RIC Card
Fiber Connectors on an 155 SM/MM CRS Card
DLP-702
Nmic Nmic a
Modifying the Nmic IP Address
Changing the IP Address of a Nmic
Nmic a Nmic B
DLP-702
Nmic IP Addresses and IP Masks Definitions Command Line
Bringing UP the Cellworx Graphical User Interface
Nmic Craft Port Pin Out Information
Logon to Remote Node Craft Session VIA Telnet from GUI
GUI Remote Craft Logon Pop-up Window
Remote Craft Logon Screen
DLP-704
Nmic EIM LAN Port Connection
Launch the Graphical User Interface GUI
Nmic GUI Network Display example
Perform Discovery on a NEW Cellworx STN Ring Network
DLP-706
Stop! You have completed this procedure
Cellworx Vision Help Contact Window
Cellworx Vision Turn-up Ring Pull Down Menus
Order of Connectivity
Cellworx Vision NE Order Verification
Cellworx Vision Current Status Window, NE Boot Process
Cellworx Vision Information
Cellworx Vision
14. Cellworx Vision Redrawing Icon Layout
16. Save New Icon Coordinates
17. Save Icon Layout Confirmation
Absolute
Time and Date
Cellworx Vision Time and Date Pull Down Menu
DLP
Create AN ATM or CES Connection
DLP-708
YES
Traffic Policing Attributes for Various Service Categories
CBR.1 VBR.1 VBR.2 VBR.3 UBR UBR.1
Cellworx Vision GUI Configuration Pull Down Menu
Cellworx Vision ATM Virtual Connection Configuration Window
CES ATM VP Connection Configuration Window
Cellworx Vision ATM Virtual Path Connection Configuration
Configure or Delete a Traffic Contract
User Selectable Service Class Types and Parameters
Delete a Traffic Contract
Cellworx Vision Configure Traffic Contract Window
Cellworx Vision Traffic Contract Configuration Completed
? Delete selected traffic contract? OKCancel
Traffic Contract ********** already exists
View Connections
Cellworx Vision Connection Menu Tree
CES -VC
ATM VP ATM VP
ATM VC ATM VC
CES CES
ATM
Cellworx Vision Subnetwork Connections Screen
Cellworx Vision Connection Deletion Confirmation Window
Cellworx Vision Subnetwork Connection Status Window
Cellworx Vision Subnetwork Connection Configuration
NDC
LOG OFF of Cellworx STN Graphical User Interface
Save icon layout before exiting? Exit Cellworx? Yes
ADD Expansion Shelves STN-EPS
DLP-712
Cellworx Vision Add an Expansion Node Pull Down Menu
Cellworx Vision Adding an STN-EPS ID Window
Add EPS NE Error Message
Add EPS NE Reconnect Cables Instructional Window
11. Cellworx Vision Software Selection Instructional Window
GNE-1
Display Network Alarm Summary
Cellworx Vision Fault Pull Down Menu
Cellworx Vision Alarms
Nmic
Cellworx Vision Alarm Filter
T3 CRS, T3 TMUX, Tmux EXP
Cellworx Vision Alarm Filter Severity List
Configure Service Provider Profile
Cellworx Vision Configure Service Provider Profile Menu
Cellworx Vision Service Provider Call Type Pull Down Menu
View Ring Resource Usage
Cellworx Vision View Ring Resource Usage Pull Down Menu
Cellworx Vision Ring Resource Usage Window
View Fiber Bandwidth Usage
Cellworx Vision View Fiber Bandwidth Usage Pull Down Menu
Cellworx Vision Network Fiber Bandwidth Usage
Configure NE Alarm Threshold
Cellworx Vision GUI Fault Pull Down Menu
Alarm Severity List
Alarm Threshold Configuration Window
Cellworx Vis on Configuration Pull Down Menu
Refresh Topology
Cellworx Vision Configuration Pull Down Menu
Force Network Discovery
Cellworx Vision Error
Software Selection
Please select a network element first
Cellworx Vision Informational Message
Selecting a New Software Version
Software Upgrade Confirmation Message
About NE
NE Selection and Pop-up Menu Window
About NE Informational Screen
Nmic System File Replication
Cellworx Vision Nmic Platform Menu Tree
Cellworx Vision system File Replication Window
Changing Connection Configurations
Change CONFIGURATION/TEST AN Existing Connection
Testing Connections
View Connection Pull Down Menu
Subnetwork Connection Filter Window
Subnetwork Connection Configuration Window
Subnetwork Connection Configuration Options
Nmic Protection
Nmic Switchover Confirmation Window
Cellworx Vision Nmic Protection
Nmic Protection Restoration
Nmic Protection Restoration Window
Protection restoration is not needed
DLP-726
Threshold Configuration
Performance Monitoring Selection Window
Sefs SES
Sonet PM Values
SES-PFE
SES-LFE
UAS-LFE
UAS-PFE
DLP-727
Performance Monitoring Selection Criteria Screen example
SES UAS BES Sefs
CV-L ES-L
UAS Sefs
T3 Tmux Multi 1 Performance Monitoring Values
Been reset to zero by a user during the reporting period
SET / Retrieve T3 CRS Performance Monitoring Statistics
T3 CRS PM Selection Criteria Window
T3 Performance Monitoring Values
PES Pses Sefs UAS CV-L ES-L PCV CCV CES Cses
Cells Out Cells HEC Viols OCDs
DLP-729
T1 Multi 1 CRS PM Selection Criteria Window
CV-L ES-L SES CV-P UAS BES CSS Sefs
Bits
Retrieve Network Data Collection NDC Statistics
View Connection Pull Down Menu
Select Interval Window
VPI VCI
NDC Data Statistics
NE ID
Disc CLP=0
Ring Upgrade Procedure
DLP-731
Ring Upgrade Pull-Down Menu
Ring Audit Window example
Ring Upgrade Configuration Window
Please install the new 2488 Ring RICs in slot
Wait for the 2488 Ring RICs in slot 16 to boot
11. Ring Upgrade Confirmation Message
Actual Ring
12. Ring Upgrade RIC Status Window for 2488 RICs in Slot
14. Ring Upgrade Confirmation Message
Ring Upgrade Successfully completed
SET / Retrieve FT1 FRS Performance Monitoring Statistics
FT1 FRS PM Selection Criteria Window
Threshold Configuration Screen
SET / Retrieve FE1 FRS Performance Monitoring Statistics
FE1 FRS PM Selection Criteria Window
FE1 FRS
About
Help
Contact
Cellworx Vision About Window
Revert to Saved Icon Layout
Cellworx Vision Save Icon Coordinates Warning Message
Save NE Icon Layout Pull Down Menu or Diskette Icon Tool
Cellworx Vision Save Icon Layout Verification Window
? Save icon layout before exiting? YesNo
ADD a Ring Network Element
DLP-737
10966-E
Cellworx Vision Add Ring NE Task Overview
Cellworx Vision Add Ring NE Enter ID Window
Cellworx Vision Add NE ID Informational Window
Cellworx Vision Add NE Boot Time Exceeded
10. Add EPS NE Reconnect Cables Instructional Window
Cellworx Vision Retry?
ADD a Second Network Element
Stop! You have completed this procedure
Cellworx Vision Add Second Ring Task Overview Window
Cellworx Vision Add Ring NE Connect Fiber
Cellworx Vision Add EPS NE Boot Time Exceeded
Cellworx Vision Configure Software Window
12. Cellworx Vision Updating Topology Message Window
Delete Connections
Stop! You have completed this procedure
Connection
Subnetwork Connection Filter Window Network
NE-1-- NE-2 Incomplete Functional Unknown State
DLP-740
Cellworx Vision Remove Ring NE Pull Down Menu
Network Element 1 id
Cellworx Vision Redrawing Icon Layout
Save New Icon Coordinates
Retrieve Logs from the Nmic VIA FTP
Cd /cellworx
Mget /cellworx/performance/ne3
Retrieve Compressed Logs from the Nmic VIA FTP
Tar -zcvf /tmp/perf050500.tar.gz performance
Ftp cd /tmp
This page intentionally left blank
Reflash Boot Image
NE Pop-up Window
Backing UP a Copy of the Nmic Database
Saving the System Database
Saving System Database
Cp Nmic NMIC.backup
Delete a Cellworx STN Expansion Shelf EPS
Cellworx Vision Remove EPS NE Task Overview
Removed EPS Successfully Message Window
SET E1 Multi 1 Card Configuration
ATM Interface Configuration CRS Mode
CES Interface Configuration
E1 Multi 1 Card Configuration Window
E1 Multi 1 Configuration Options
ATM VPI ATM VCI
ATM Interface Configuration Options for CRS Mode
E1 Multi 1 Configuration Options for CES Mode
E1 Multi 1 ATM Interface Options
SET SC Card Configuration
Shelf Level GUI Chassis View Window
Bit Rate Parity Data bit Stop bit Inactivity Time-out
Shelf Level GUI Configuration Pull Down Menu
SET Shelf Timing Resource
PRS ST2 ST3 SMC DUS
BSF
PRS ST1 ST2 ST3 SMC DUS ESF B8ZS AMI
AIS
ESF B8ZS
SET Shelf Housekeeping Alarm Configuration
Shelf Level GUI Fault Pull Down Menu
HSK ALM-3
Node Name Cellworx1 Node Id Alarm String State HSK ALM-1
HSK ALM-2
HSK ALM-4
SET 622 Ring Interface Card RIC Configuration
Default Options Definition
NRZ
Sonet
Sonet SDH
ATM Interface Configuration
SET 155 SM/MM CRS Card Configuration
Card and Port Configuration
Selection Default Options Definitions
ATM Interface Configuration Options
4of ATM Interface Configuration Options
SM/MM CRS ATM Port Interface Configuration Screen
SET T3 CRS Card Configuration
EPS
Locked Unlocked
Plcp
Sets the maximum number of VPCs that may be
T3 CRS ATM Interface Screen
SET T3 Tmux Multi 1 and Tmux EXP Card Configuration
T3 Tmux Multi 1 Card Configuration Window
T3 Tmux Multi 1 Card Configuration Options
B3ZS
Unlocked
Ansi T1-403 FDL
ATM VPI
E1 Multi
SET T1 Multi 1 Card Configuration
T1 Multi 1 Card Configuration Window
B8ZS AMI
T1 Multi 1 Configuration Options
Service Type
ANSI-T1-403 FDL
UNI NNI
T1 Multi 1 ATM Interface Options
SET 2488 Ring Interface Card RIC Configuration
Admin State
Sonet
RIC Configuration Options
Retrieve SC Card Status
SC Card Status Window
Shelf Controller Status Definitions
Timing Reference Status Definitions
DB7 DB8
ST3 PRS STU ST2 SMC DUS
PRC PRS SEC SSU ST1 STU ST2 ST3 SMC DUS
SET 155 Ring Interface Card RIC Configuration
RIC Configuration Screen RIC Configuration Options
Sonet
Retrieve 622 Ring Interface Card RIC Status
RIC Status Window
AIS RDI
RIC Card Status Definitions
LOS LOF
RIC Status Definitions
STS LOP STS AIS STS RDI
Retrieve 155 CRS Status
CRS Card Status Window
LOS
CRS Card Status Definitions
Section Status
STS LOP
Card Status Definitions
STS AIS STS RDI
Retrieve T3 CRS Card Status
T3 CRS Card Status Window
T3 CRS Card Status Definitions
Display T3 Card Status Definitions
LOF LOS
Retrieve T3 Tmux Multi 1 Card Status
Controller Card Level View Changes Shelf Level View
Availability Status Protection State
LOF LOS
DS1 Channel Status Window
T3 Tmux Multi 1/TMUX EXP DS1 Port Status Definitions
Retrieve 155 Ring Card Status
Ring Card Status Display
RIC Card Status Definitions
Path Status Sync Status S1 Received Path Trace J1 No Alarm
Retrieve T1 Multi 1 Card Status
T1 Multi 1 Card Status Window
Display T1 Multi 1 Card Status Definitions
Line State
Configure Card Protection Groups
Protection Groups and Protection Switch GUI Screen
T3 EXP
Card Protection Schemes
T3 CRS
Perform Diagnostics on Optical Cards
Shelf Level GUI Chassis View Display
Location 5th Avenue
Transmit for Section Line Path BIP Command Duration
Node Name Cellworx
SET System Identifier
Cellworx Vision Chassis View
SET Craft User Configuration
Privilege Level
Delete
User Account Privilege Levels
SET Craft Menu Configuration
Cellworx Vision Chassis Level Display
Craft Menu Configuration Display
Chassis View Configuration Pull-down Menu
Hardware Inventory
Hardware Inventory Display
Initiate a Protection Switch
Protection Switch Screen
Protection Switch Command Definitions
Looback Test
RIC Card Configuration View
Loopback Screen Options
Loopback Direction and Signal Flow Diagram
Card and Shelf Reset
Card Reset Display Level Card Reset Level Definitions
Card Reset Confirmation Message
Finding and Changing the Nmic IP Address
Shutting Down the Nmic
Nmic Shut Down Commands
Configuring the Nmic IP Address
PC/Laptop Display Parameters
Telnet and Configuration Initialization
Telnet to the Nmic
ADD or Change AN Snmp Trap Host on the Nmic
Unmodified Snmp Trap Host File
Modified Snmp Trap Host File
Alarm CUT-OFF ACO
Shelf Level Alarm Cut-Off Window
Remove AND/OR Replace Cellworx Cards
Removing a Front Access Card or EIM from the Shelf
Example of Seating a Front Access Card or EIM in a Shelf
Ending a GUI Session Following AN Abnormal Session Ending
Terminal Display for Managing GUI
Retrieve 2488 RIC Status
Cellworx Vision Card View OC3c/STM1 Ring Interface Card
RIC Card Status Definitions
RIC Status Definitions
Delete Incomplete Connections
To 3.0 Software Release Upgrade Procedure
Place System Into Steady State
Save Databases
Copy Databases to AN External Device
Cd /cellworx/phase2.0dbs
FTP Software to Each Nmic
Ftp IP address of the slot4 Nmic
Install NEW Software Onto Nmic
Sbin/cwupgrade /tmp/p3/AicSccSwImages-3.0.1-2.ppc.rpm
Upgrade the Active Nmic Slot
Download New Flash Images to SCCs and SEPICs
Sbin/reboot
Upgrade the Bootrom Flash
AIC/RIC =
Rm -f /cellworx/flashImage/aic/bootromVer2/bootrom.2.1.0.25
Nmic RS232 Port Cable Connector Wiring
Removing a Nmic Card from the Shelf
Example of Removing a Front Access Card
Example of Seating a Front Access Nmic Card
Rebooting the System Using a Saved or Default Database
FTP Remote Database Files to the Nmic and Reboot the System
Ftp bin Ftp hash optional Ftp prompt optional
Mv /tmp/NMIC /tmp/NE.* /cellworx/config
Mv NMIC.backup Nmic
Rebooting the System Using the Default Database
Rm /cellworx/config/NE.?
ADD/DELETE GUI Users or Change GUI User Level Security
Mkuser username GUI access level
Create a NEW User
View ALL Active GUI Users
Terminal Display of Managing GUI
Change User Access Level
Remove a User
SET FE1 FRS Card Configuration
FRS Port Configurations
DLP-784
FE1 FRS Card Configuration Window
FRS Buffer Congestion Threshold Settings
HDB3 E1 MF
FE1 FRS Card Configuration Options
FRS
E1 CRC-4 MF
Default All 0s
UNI FRF.5
UNI NNI FRF.5 FRF.8
SET FT1 FRS Card Configuration
DLP-785
FT1 FRS Card Configuration Window
Onset
ANSI-T1-403
FT1 FRS Configuration Options
Received
FDL
FT1 FRS Interface Configuration Window
Frame Relay Interface Configuration Options
Create a Frame Relay Connection
FR Endpoint Parameter Definitions
ATM OAM
DE=CLP
Sscs LMI
CLP=DE CLP=0 CLP=1
FR-ATM VC Connections
Creating FR Traffic Contracts
Cellworx User root Local Time GMT Time 10905-E
Connection Configuration Window
FR-FR Connection Configuration Window
FR-ATM VC Connection Configuration Window
FR Connection Configuration Create a Traffic Contract
Create AN ATM VP Multicast Connection
DLP-787
DLP-787
DLP-787
Stop! You have completed this procedure
ATM VP Multicasting Configuration Screen
VPI VCI
VP Multicast Connection Traffic Contract Selection Window
GUI Connection Menu Tree
Connection Network Traffic
ATM VP Multicast Connection List Screen
11. ATM VP Multicast Leaf Endpoint Status Window
Retrieve FT1 FRS Card Status
FT1 FRS Card Status Window
Display FT1 FRS Card Status Definitions
LOF XMT AIS LOS
LOF RCV AIS
Lomf
Retrieve FE1 FRS Card Status
FE1 FRS Card Status Window
Display FE1 FRS Card Status Definitions
No Alarm RCV Far End
Create AN ATM VC Bundled Multicast Connection
DLP-790
DLP-790
DLP-790
DLP-790
Stop! You have completed this procedure
Cellworx Vision GUI Configuration Pull Down Menu
ATM VC Bundled Multicasting Configuration Screen
ATM VC Bundled Multicasting VCI Mapping
UNI ICI
ATM VC Bundled Multicasting Traffic Contract
Create a Traffic Contract
Connection Network Traffic
11. ATM Bundled VC Multicast Connection List Screen
13. ATM Bundled VC Multicast Leaf Endpoint Status Window
DLP-791
Deleting Connections
Stop! You have completed this procedure
Connection Network Traffic
ATM Bundled VC Multicast Connection List Screen
ATM Bundled VC Multicast Configuration Window
Add Leaf Window Configure Endpoint
SET T3 CES Card Configuration
T3 CES Configuration Screen T3 CES Configuration Options
T3 CES Interface Configuration Screen
T3 CES Interface Configuration Options
Srts
Retrieve T3 CES Card Status
T3 CES Card Status Window
T3 CES Card Status Definitions
Display T3 CES Card Status Definitions
SET / Retrieve T3 CES Port Performance Monitoring Statistics
T3 CES PM Selection Criteria Window
SEs LCs BUs BOs SCIs DCs
To 3.1 Software Release Upgrade Procedure
Delete Incomplete Connections
Save Databases
Copy Databases to AN External Device
FTP Software to Each Nmic
Cd /cellworx/release3.0dbs
Telnet IP address of slot4 Nmic
Install NEW Software Onto Nmic
Sbin/cwupgrade /tmp/p3.1/cellworx-3.1.0.1-1.ppc.rpm
Upgrade the Standby Nmic Slot
Cd /cellworx/swImage/swLoadVer3/nmic.3.1.0.1/bin
DLP-795
DLP-795
Upgrade the Bootrom Flash
GUI Main Screen example
Retrieve 622 CRS Status
Loss Of Signal. Cannot locate
Card Status Definitions
SET 622 SM CRS Card Configuration
Stop! You have completed this procedure
Card Dependant User defined
SM CRS ATM Port Interface Configuration Screen
Software Fallback from Release 3.1 to Release
Telnet IP address of the slot2 Nmic
Flash Fallback
Software Fallback
Stop! You have completed this procedure
Philosophy of Maintenance
Troubleshooting Guidelines
Alarm Troubleshooting
Reference NTP-007
Alarm Identifications
Bit Coding Violations Threshold Crossing Alert
Bit Errored Seconds Threshold Crossing Alert
Bit Severely Errored Seconds Threshold Crossing Alert
Cellbus Parity Threshold Crossing Alert
Code Violation Line Far End Threshold Crossing Alert
Control Slip Seconds Threshold Crossing Alert
Configurat ion Failure
Code Violation Threshold Crossing Alert
Threshold Crossing Alert
Endpoint
Endpoint Alarm Indication Signal
EIM Removed Egress Congestion High Threshold Crossing Alert
Loss
Errored Seconds Line Far End Threshold Crossing Alert
Far End Loss Critical
LOS-FE
Far End Loss
Errored Seconds Threshold Crossing Alert
AlarmX
Far End
Failure
Login
Seconds Threshold Crossing Alert
Cell
New
NE Power Failure a
Module Minor Failure With Protection ModuleFail
Path Trace
Payload Label Mismatch Path
Out Cell Delineation Threshold Crossing Alert
Path Coding Violations Threshold Crossing Alert
PLM-P
Physical Layer Convergen ce Protocol Yellow Alarm
Physical Layer Convergen ce Protocol Loss of Frame
Protocol Error Threshold Crossing Alert
Protection Switch Failure
Protection Switch Successful
Remote Failure Indication
LFETca
Remote Major Service Failure Affecting Indication Line
Secondary Major Not service Derived Affecting
Severely Errored Seconds Line Threshold Crossing Alert
Shelf Controller
Signal Degraded Software Downloadi ng Failed
T1 Yellow Alarm
Removed
Unavailable Seconds Line Far EndThreshold Crossing Alert
T3 Remote Alarm Indication
T3 Loopback
Unavailable
Unavailable Seconds Path Threshold Crossing Alert
Unavailable Seconds Threshold Crossing Alert
NE Flowchart Troubleshooting Guide
Nmic Generated Alarms
Alphabetical Nmic Generated Alarm Reports
Protection Change Notification
WARRANTY/SOFTWARE
REPAIR/ADVANCE Replacement Policy
Returned Material
REPLACEMENT/SPARE Products
Repair Charges
Customer Information and Assistance
Top
Page
Image
Contents