ADCP-70-220 Issue 1 November 2000 Section 2 Operation and Maintenance

NTP-009

Page 1 of 1

ADDING SERVICES TO A CELLWORX STN NODE

Summary: This procedure outlines the steps involved for assigning card, port, and user level parameters for individual interface cards and configuring protection operation for grouped interface cards within each node. The cards must be physically equipped within a shelf before the slots can be configured via the software.

1.Verify the cards to be provisioned are physically equipped within the shelf by double clicking on the node to open a shelf level GUI display. Each card should have a green status indicator.

Note: Applications using the 19-inch chassis will show card slots 1 through 18 but only card slots 1 through 11 and 16 through 18 are programmable.

2.Refer to the Cellworx STN Installation manual for card installation procedures if cards are not currently equipped,

otherwise continue.

1152693

3. To remove or install cards currently in the chassis, refer to:

DLP-777

4.Set the configuration options for the following cards when equipped:

Set the E1 Multi 1 Card configuration.

DLP-747

Set the 622

RIC card configuration

DLP-751

Set the 155

CRS card configuration

DLP-752

Set the 622

CRS card configuration

DLP-797

Set the T3

CRS card ATM configuration

DLP-753

Set the T3

TMUX Multi 1 card configuration.

DLP-754

Set the T1

Multi 1 Card configuration.

DLP-755

Set the 2488 RIC card configuration options.

DLP-756

Set the 155

RIC configuration options.

DLP-758

Set the FE1 FRS Card configuration.

DLP-784

Set the FT1 FRS Card configuration.

DLP-785

Set the T3

CES Card configuration

DLP-792

5.Configure card protection groups if applicable for each group of

interface cards.

DLP-765

6.Close the card configuration window to return to the shelf display. Verify that the required cards are in-service by the green status indicator.

7.Perform acceptance tests on the new access cards when

applicable.

NTP-011

Stop! You have completed this procedure.