1152700 Issue 1 February 2001 Section 2 Operation and Maintenance

DLP-751

Page 3 of 3

Table 751-1. 622 RIC Card Configuration Options, continued

SELECTION

DEFAULT

Signal

5

Degrade BER

 

Threshold

 

Medium Type

SONET

 

 

OPTIONS

5 through 9

SONET

SDH

DEFINITION

Defines the number of bit errors the port can incur before a signal degrade occurs and generates an alarm message and probably protection switch.

Not configurable on RIC. This is determined by the dipswitch on the SC EIM, which sets the shelf type. Can be SONET, Synchronous Optical Network, US, or Synchronous Digital Hierarchy, European standard for transporting data over fiber.

Loopback towards

Line Coding

Line Type

Transmit Path Trace

1

None

NRZ

Card Dependant

(example)

NE1_Slot17_ Port1 (OC12)

None

Terminal

Facility

SonetOther

sonetShortSingle Mode

sonetLongSingle Mode

sonetMultiMode

No loopback activated on this card.

Sends cells back to the cellbus and back out to the ring. No changes are made to the path layer data.

Loops the incoming signal back to the CPE and generates AIS to the cellbus.

Not configurable by user.

Not configurable by user, dependant on card type inserted.

Card position dependent. This is assigned by the system according to the NE and slot it is equipped in.

Page 2-236

© 2000, ADC Telecommunications, Inc.

Page 256
Image 256
ADC Release 3.1 user manual Sonet SDH, Nrz