1152700 Issue 1 February 2001 Section 2 Operation and Maintenance

DLP-717

Page 1 of 2

CONFIGURE NE ALARM THRESHOLD

Summary: This procedure describes the steps necessary to set the alarm reporting thresholds for each NE in the network. The alarm threshold setting determines the minimum alarm severity for a node to report to the GUI screen, for instance, if a node was set to Major, any minor conditions would not be reported via the GUI screen icon for that node.

1.From the GUI main screen, select Fault to open the pull down menu, and select Configure NE Alarm Threshold either using the mouse or by entering Alt+A, and Alt+C. Refer to Figure 717-1. The user may also right click on an NE and select the Configure Threshold Alarm option.

2.The Cellworx Alarm Threshold Configuration window appears. Refer to Figure 717-2. Select a node from the list provided under Domain.

3.Select the lowest alarm severity to be emitted from the selected node from the list provided on the right. Refer to Table 717-1for definitions of each severity.

4.Select Apply to enable the new parameters. A confirmation window should appear similar to Figure 717-3. Dismiss the confirmation window by clicking OK and close the Alarm Threshold Configuration screen.

Stop! You have completed this procedure.

Cellworx Vision Subnetwork Management System

File Configuration

iFault Performance

Alarms

Configure NE Alarm Threshold...

NMIC Protection

NMIC Protection Restoration

10916-D

Figure 717-1. Cellworx Vision GUI Fault Pull Down Menu

Page 2-119

2000, ADC Telecommunications, Inc.