ADC Release 3.1 user manual Mating, Attenuators, Adapters

Models: Release 3.1

1 489
Download 489 pages 5.8 Kb
Page 71
Image 71

1152700 Issue 1 February 2001 Section 2 Operations and Maintenance

DLP-701

Page 6 of 10

16.Moisten, but do not saturate, the pad with alcohol making a spot approximately 1/2" in diameter.

Note: Alcohol should only be used when connector is really dirty. A fiber cleaning reel is always best. Use a cleaning reel even after alcohol to remove residue. Do not consume isopropyl alcohol at anytime.

17.Press the ferrule end face into a wet spot on the wipe. Using force, twist the ferrule so that a hard wiping action takes place. Repeat twice, using a clean alcohol-moistened area each time.

18.Press the ferrule end face into a dry spot on the wipe. Using force, twist the ferrule so that a hard wiping action takes place.

19.Discard the used pad.

Attenuators

20.For an exposed ferrule (in-line type), see connector cleaning procedure; blow the other end dry with clean compressed air.

21.Clean bulkhead attenuators only by blowing with clean compressed air.

Adapters

22.Moisten one end of a lint free adapter cleaning tips with alcohol.

23.Remove excess alcohol from the adapter cleaning tips with a clean wipe.

24.Insert the moistened adapter cleaning tips into either end of the adapter and scrub in and out so that the inside surface of the adapter is wiped by the pipe cleaner. Repeat this step for the opposite end.

25.Insert the dry end of the adapter cleaning tips into either end of the adapter to remove any residual alcohol. For oversized adapters (biconic), stir the adapter cleaning tips for better surface contact. Repeat this step for the opposite end.

26.Blow the adapter dry with clean compressed air.

MATING

FC

27. Insert the ferrule tip into the adapter.

Page 2-51

© 2000, ADC Telecommunications, Inc.

Page 71
Image 71
ADC Release 3.1 user manual Mating, Attenuators, Adapters