1152700Issue 1 February 2001 Section 2 Operations and Maintenance

TAP-100

Page 13 of 23

Table 4-1. Alarm Identifications, continued

ALARM MESSAGE

SEVERITY

IMPACT

 

DESCRIPTION

 

SUGGESTED COURSE OF ACTION

 

 

 

 

 

 

 

 

Out Of

Cell

Delineation

Threshold

Crossing

Alert

OCDThresh oldExceede d

Information al Alert

Installation Error

Can indicate line degradation.

Could be caused by a port failure at any ATM interface. Verify the port is online, check configuration, look for indications of high BER (Bit Error Rate), increase threshold settings if necessary, use line loopback to troubleshoot path through port.

Path

Coding

Violations

Threshold

Crossing

Alert

PCVTca

Payload

Label

Mismatch

Path

PLM-P

Information al Alert

Minor

Service Degradation

Installation Error

T3 P-bit coding violations threshold crossing alert.

Traffic in payload does not match what the payload label in the path layer expected.

Path code violations indicate a parity mismatch in the SONET or DSX path. Examine the physical circuit to determine if there are any impairments.

Check input source type and change payload label if needed.

P-bit

Information

Service

Errored

al Alert

Degradation

Seconds

 

 

Threshold

 

 

Crossing

 

 

Alert

 

 

PESTca

 

 

 

 

 

P-bit

Information

Service

Severely

al Alert

Degradation

Errored

 

 

Seconds

 

 

Threshold

 

 

Crossing

 

 

Alert

 

 

PSESTca

 

 

 

 

 

Page 2-432

© 2000, ADC Telecommunications, Inc.

T3 P-bit errored seconds threshold crossing alert. A one second interval in the transmission from the far end originating NE has had excessive parity errors. PES errors have exceeded the user definable threshold level.

T3 P-bit Severely Errored Seconds (SES) threshold crossing alert. Excessive one second intervals in the transmission from the far end originating NE have had Parity bit errors. P-Bit SES errors have exceeded the user definable threshold level.

Parity bits on the incoming DS3 line. The transmitted signal does not match the received signal.

Parity bits on the incoming DS3 line. The transmitted signal does not match the received signal at an error rate of 1.6E-5 or worse for a period of time less than ten seconds.

(continued)

Page 476
Image 476
ADC Release 3.1 Out Cell Delineation Threshold Crossing Alert, Path Coding Violations Threshold Crossing Alert, Plm-P