ADC Release 3.1 user manual Cd /cellworx/phase2.0dbs, FTP Software to Each Nmic

Models: Release 3.1

1 489
Download 489 pages 5.8 Kb
Page 349
Image 349

1152700 Issue 1 February 2001 Section 2 Operations and Maintenance

DLP-780

Page 3 of 10

7.Within the cellworx directory on the external workstation, make another directory called release1.2_dbs by entering the following command:

mkdir /cellworx/phase2.0_dbs

8. Change to the new directory by entering the following command:

cd /cellworx/phase2.0_dbs

9.From the Workstation shell, establish an FTP connection to the slot_2 NMIC by entering the following command:

ftp [IP address of slot_2 NMIC]

10.Log into the NMIC as “cellworx” and enter the cellworx password. The default password is blank so the user may elect to press Enter or Return or enter the cellworx password set by the user followed by Enter or Return.

11.At the FTP prompt, set the binary file transfer mode by entering the following command:

bin

12.At the FTP prompt, change to the directory created earlier on the slot_2 NMIC by entering the following command:

cd /cellworx/config/phase2.0_dbs

13.At the FTP prompt, retrieve (get) all the files in the current directory by entering the following command:

mget *

14.At the FTP prompt, exit the FTP session by entering the following command:

bye

FTP SOFTWARE TO EACH NMIC

Summary: The software needed for upgrading each NMIC must be transferred from an external source (most likely a Cellworx CD), to each NMIC. Use the slot 2 NMIC shell from the previous steps to upgrade the slot 2 NMIC. Log into the slot 4 NMIC as the root user from a separate shell to upgrade the slot 4 NMIC.

Note: Keep both NMIC shell windows open. They will be used throughout the upgrade process.

telnet [IP address of the slot 4 NMIC]

Page 2-329

© 2000, ADC Telecommunications, Inc.

Page 349
Image 349
ADC Release 3.1 user manual Cd /cellworx/phase2.0dbs, FTP Software to Each Nmic