1152700 • Issue 1 • February 2001 • Section 2 Operation and Maintenance
Page 2 of 5
TESTING CONNECTIONS
5.To enable Network Data Collection (NDC) on the connection for either ingress or egress, click anywhere on the box or text next to it that reads Ingress NDC or Egress NDC.
6.To test the connection selected and displayed on the Subnetwork Connection Configuration window, click on the box next to Test Type which should currently read “No Test” if no test has been previously initiated on it. The selection window appears displaying the following options:
•No Test – No test is in progress or requested.
•
•Segment End Loopback –
•Continuity Check Source –
•Continuity Check Sink –
7.At the Loopback Location ID field, enter a unique ID identifying the location that the loopback cells are being generated from.
8.At the Insert Loopback Cells field, either leave the selection on Towards Access Facility which will loop the incoming cells back out to the AIC cards in the system, or click on the textbox and drag downwards to select Towards Ring Facility to loop the cells incoming from the RIC cards back out to the Ring.
9.The Test Status display indicates whether the connection is currently under test. Clicking on the Test Status button below it will refresh the status display and the Abort Test button will abort the test.
Cellworx Vision Subnetwork Management System | ||
File Configuration Fault Performance | ||
Time and Date |
| |
Connection | Create... | |
| ||
Topology | View ... | |
Software | Configure Traffic Contract ... | |
Configure Service Provider Profile ... | ||
NMIC Platform | ||
View Ring Resource Usage ... | ||
| ||
| View Fiber Bandwidth Usage ... | |
|
Figure 723-1. View Connection Pull Down Menu