
1152700 • Issue 1 • February 2001 • Section 2 Operations and Maintenance
Page 1 of 6
VIEW CONNECTIONS
Summary: This procedure describes the steps necessary to successfully navigate the Cellworx Vision Graphical User Interface to view the established connections. The connection information can be used for checking new connections, viewing existing connections, or to view possible connection problems on the ring. For multicast connections, refer to
1.Access the Subnetwork Connection Filter window using one of the following methods:
a.Using the left mouse button, select Configuration, Connection, and View. Refer to Figure
b.Using the direct selection keys, enter Alt+C, Alt+N then Alt+V. Refer to Figure
c.Using the right mouse button, position the cursor over the NE, click and hold the button, select View Connections, and release the button.
d.Using the left mouse button, select the connection icon above the workspace.
2.The Subnetwork Connection Filter window appears. Refer to Figure
3.Once the desired information is selected, select Apply using the left mouse button.
4.The Subnetwork Connections window appears as shown in the example in Figure
5.If a connection is displayed as INCOMPLETE, the user may select it and then select Retry to attempt to establish the connection.
6.The user may delete a connection, or multiple connections, by selecting them using the left mouse button, and then selecting Delete. A confirmation message will appear as shown in Figure
Page
© 2000, ADC Telecommunications, Inc.