ADC Release 3.1 user manual Line State

Models: Release 3.1

1 489
Download 489 pages 5.8 Kb
Page 306
Image 306

1152700 Issue 1 February 2001 Section 2 Operations and Maintenance

DLP-764

Page 3 of 3

Table 764-1. Display T1 Multi 1 Card Status Definitions, continued

ITEM

Line State

STATUS

No Alarm

Rcv AIS

RCV Far End

LOF

Xmt RAI

Alarm

Xmt Far End

LOF

Xmit AIS

LOF

LOS

Loopback

State

Rcv Test Code

Other Failure

DEFINITION

T3 line is operating within normal parameters.

Card transmitting a Remote Alarm Indication signal (RAI) to customer equipment.

Card receiving a Loss Of Frame indication from far end NE.

Access interface (AIC) Receiving Remote Alarm Indication.

Transmit Far End Loss of Frame

Card is transmitting an Alarm Indication Signal (AIS).

Input signal frame format not recognized.

No input signal being received.

Card has been manually set to loop signal back to customer equipment.

Card is receiving a test signal input.

Card is experiencing a failure other than these listed.

ACTION

No action required.

Check VP connection per DLP-709, and remote transmit end.

Check VP connection per DLP-709, and local access interface.

Check remote end T3 input signal.

Check local T3 signal input.

Verify correct frame format setting and change if needed per DLP-755.

Check metallic input and DSX.

Check customer end for troubleshooting activity. If required, release loopback per DLP-772.

Check with administrator for testing activity.

Page 2-286

© 2000, ADC Telecommunications, Inc.

Page 306
Image 306
ADC Release 3.1 user manual Line State