1152700 Issue 1 February 2001 Operation and Maintenance

DLP-789

Page 3 of 3

Table 789-1. Display FE1 FRS Card Status Definitions, continued

ITEM

Line State

STATUS

No Alarm

RCV Far End

LOF

RCV AIS

RCV Far End

LOMF

RCV Test

Code

XMT Far End

LOF

XMT AIS

LOF

LOS

Loopback

State

Other Failure

DEFINITION

FE1 line is operating within normal parameters.

Receive Far End Loss of Frame

Card transmitting a Remote Alarm Indication signal (RAI) to customer equipment.

Card receiving a Loss Of Multi-Frame indication from far end.

Card is receiving a test signal input.

Transmit Far End Loss of Frame

Card is transmitting an Alarm Indication Signal (AIS).

Input signal frame format not recognized.

No input signal being received.

Card has been manually set to loop signal back to customer equipment.

Card is experiencing a failure other than these listed.

ACTION

No action required.

Check connection per DLP-709, and local access interface.

Check connection per DLP-709, and remote transmit end.

Check connection per DLP-709, and local access interface.

Check with administrator for testing activity.

Far end NE has lost it’s framing, near end is transmitting alarm back.

Check local FE1 signal input and EIM.

Verify correct frame format setting and signal input.

Check signal input at EIM and DSX.

Check customer end for troubleshooting activity. If required, release loopback per DLP-772.

Take appropriate actions according to local practices.

Page 2-391

© 2000, ADC Telecommunications, Inc.

Page 411
Image 411
ADC Release 3.1 user manual No Alarm RCV Far End