ADC Release 3.1 user manual Availability Status Protection State

Models: Release 3.1

1 489
Download 489 pages 5.8 Kb
Page 297
Image 297

1152700 Issue 1 February 2001 Section 2 Operations and Maintenance

DLP-762

Page 3 of 6

Table 762-1. Display T3 TMUX Multi 1 and TMUX EXP Card Status Definitions, continued

ITEM

Availability Status

Protection State

STATUS

Available

In Test

Failed

Power Off

Not Installed

Off Line

Dependency

Unknown

Not Protected

Enabled

Manual switch

Forced Switch

Lockout

Unknown

DEFINITION

Card is ready for processing commands.

Card is currently processing test signals.

Card has failed operation and system has placed it out of service.

No power to the card.

Card is not currently installed in selected slot of the shelf.

Card is installed and provisioned but currently off line.

Card is supplying timing reference, traffic, or other data to the system.

The system processor does not currently know the availability status.

Not Protected

Protection is available for selected card but is not active.

User has manually switched the card to protection.

User has forced card to protection.

Card cannot switch to protection. It has been locked out by command or switch count.

Protection status information is not available to the shelf controller.

ACTION

No action required.

Wait a few seconds for screen to update.

Card may be performing a reset, or the bus may be busy.

Check power source, replace card if source is good per DLP-777.

If required, install card in selected slot per DLP-777 and provision per DLP-754.

If required, set module on line per DLP-754.

Perform a soft switch over (manual) per DLP-771 to release card dependency if removing.

Wait for processor to update current status, may need to perform a manual reset of SC per DLP-773.

If equipped, set up a protection group and provision card for protection per DLP-753.

No action necessary.

If required, switch the card back per DLP-771.

If required, release forced switch per DLP-771.

If required, release manual lock-out per DLP-771.

Wait a few minutes and update screen. May need to reset SC, refer to DLP-773.

(continued)

Page 2-277

© 2000, ADC Telecommunications, Inc.

Page 297
Image 297
ADC Release 3.1 user manual Availability Status Protection State