1152700 Issue 1 February 2001 Section 2 Operations and Maintenance

DLP-700

Page 1 of 1

POWER UP A CELLWORX STN NODE

Summary: This procedure provides instructions for verifying the source 48 Vdc power supply.

1.Turn on the power source that will supply power to the system.

2.Use a multi-tester to measure the DC voltage at the source. When testing, place the positive probe on the 48 V terminal and the negative probe on the COM or RTN terminal.

3.The measured voltage must be between 42.5 Vdc and 56.5 Vdc at the specified point. Was voltage within range specified? Note the polarity.

If No, proceed to step 4.

If Yes, continue with step 5.

4.The problem is in the power supply wiring or in the 48 Vdc power supply. Isolate the problem using local troubleshooting practices and correct as required before installing power to the system. Repeat procedure after correcting problem.

5.Install fuses or engage the circuit breakers that supply power to the shelf. The front access cards should illuminate. This can be verified by observing the shelf alarm indicator on the front door panel. This will only light up if the SC cards are installed and an alarm is present. Refer to Figure 700-1.

Stop! You have completed this procedure.

SHELF

ALARM

INDICATOR

DOOR

HINGES

LOWER AIR INTAKE/

CABLE ROUTING TRAY

UPPER HEAT BAFFLE/

FIBER MANAGEMENT TRAY

ESD GROUND JACK

DOOR

LATCH

10479-C

Figure 700-1. Cellworx STN Component Identification

Page 2-45

© 2000, ADC Telecommunications, Inc.