1152700 • Issue 1 • February 2001 • Section 2 Operation and Maintenance
Page 3 of 3
Table 758-1. 155 RIC Configuration Options, continued
SELECTION | DEFAULT |
Signal | 5 |
Degrade BER |
|
Threshold |
|
Medium Type | SONET |
|
|
Loopback | None |
towards |
|
|
|
OPTIONS
5 through 9
SONET
SDH
None
Terminal
Facility
DEFINITION
Defines the number of bit errors the port can incur before a signal degrade occurs and generates an alarm message and probably protection switch.
Not configurable on RIC cards.
No loopback activated on this card.
Sends cells back to the cellbus and back out to the ring. No changes are made to the path layer data.
Loops the incoming signal back to the CPE and generates AIS to the cellbus.
Line Coding
Line Type
Transmit Path Trace
NRZ
Card Dependent
(example)
NE1_Slot17_ Port1 (OC48)
sonetOther
sonetShortSingle Mode
sonetLongSingle Mode
sonetMultiMode
Not configurable by user.
Not configurable by user, type dependent on card installed. This will show sonetLongSingleMode for RICs and 155 SM cards, and sonetMultiMode for 155 MM cards.
Card position dependent. This is assigned by the system according to the NE and slot it is equipped in.
Page