1152700 Issue 1 February 2001 Section 2 Operation and Maintenance

DLP-758

Page 3 of 3

Table 758-1. 155 RIC Configuration Options, continued

SELECTION

DEFAULT

Signal

5

Degrade BER

 

Threshold

 

Medium Type

SONET

 

 

Loopback

None

towards

 

 

 

OPTIONS

5 through 9

SONET

SDH

None

Terminal

Facility

DEFINITION

Defines the number of bit errors the port can incur before a signal degrade occurs and generates an alarm message and probably protection switch.

Not configurable on RIC cards.

No loopback activated on this card.

Sends cells back to the cellbus and back out to the ring. No changes are made to the path layer data.

Loops the incoming signal back to the CPE and generates AIS to the cellbus.

Line Coding

Line Type

Transmit Path Trace

NRZ

Card Dependent

(example)

NE1_Slot17_ Port1 (OC48)

sonetOther

sonetShortSingle Mode

sonetLongSingle Mode

sonetMultiMode

Not configurable by user.

Not configurable by user, type dependent on card installed. This will show sonetLongSingleMode for RICs and 155 SM cards, and sonetMultiMode for 155 MM cards.

Card position dependent. This is assigned by the system according to the NE and slot it is equipped in.