1152700 Issue 1 February 2001Section 2 Operation and Maintenance

DLP-795

Page 7 of 11

8UPGRADE THE STANDBY NMIC (SLOT 4)

34.In the slot 4 NMIC shell, change to the directory in which the software upgrade process is located:

cd /cellworx/swImage/swLoad_Ver3/nmic.3.1.0.1/bin

35.Start the software upgrade process. (The entire procedure for upgrading the slot 4 NMIC (standby NMIC) should take no more than 15 minutes.) This step invokes a graphical procedure that is used to walk the user through all required steps for upgrading the slot 4 NMIC.

Note: The user should keep the NMIC shell open following this procedure, as a manual reboot of the slot 4 NMIC following upgrade will be necessary. At the end of this procedure, the application software on the slot 4 NMIC will be halted, and the LEDs will turn red.

36.The -h flag in the following command is used to specify the number of hours in which software fallback is allowed. Valid values are 0-168 (up to and including 7 days). The default value is 24 hours. For example, a value of 48 means the user cannot perform software fallback after 48 hours following software upgrade:

./cw_swupgrade -s 3.1.0.1 -h (hours)

9UPGRADE THE ACTIVE NMIC (SLOT 2)

37.After standby NMIC upgrade completion (the LEDs on the slot 4 NMIC faceplate should be red), start the software upgrade procedure on the slot 2 NMIC (the active NMIC). This step invokes a graphical procedure that walks the user through the necessary steps for upgrading software for the entire ring. The user should follow the directions and load release 3.1 software onto each AIC, RIC, and SCC in the ring:

cd cellworx/swImage/swLoad_Ver3/nmic.3.1.0.1/bin

./cw_swupgrade -a 3.1.0.1 -h (hours)

38.Periodically click the Refresh button on the software configuration screen(s) to see when the software download is completed for each NE. Optionally, the user may close all software configuration screens and use the Refresh button on the main status screen. Clicking this button is equivalent to clicking the Refresh button on each of the NE’s software configurations screens.

39.When the release 3.1 software download is complete for each NE, its entry in the main status screen will read, "NE is eligible for switchover." This must be done for all NEs in the ring.

Page 2-429

© 2000, ADC Telecommunications, Inc.

Page 449
Image 449