LaCie Biggest Quadra | Troubleshooting |
User Manual | page 55 |
|
|
Problem | Possible Solutions | |
The LaCie Biggest Quadra | Ensure that the interface cable (either FireWire 800 or | |
is not recognized by the | both the LaCie Biggest Quadra and the host computer. Check the LCD Display of the LaCie Biggest | |
host computer. | Quadra for error messages. | |
I was creating a RAID 5 ar- | Replace the failed disk with another disk of equal or greater capacity. The array will | |
ray, and a disk failed. What | the failed disk is replaced and the process is restarted. | |
should I do? |
| |
I only have two or three | The LaCie Biggest Quadra cannot create an array from just two disks. If you only have three disks, | |
disks. Can I still create a | you can only create a RAID 5 + Hot Spare array. The three disks must be installed in the bottom three | |
RAID array? | Drive Bays, with the top Drive Bay (the Hot Spare location) empty. | |
The LCD Display reads | The RAID Level Selector Switch is not set to the level of the existing array. In the event that the | |
“unmatched.” | RAID level does not correspond to both the disk settings and the RAID Level Switch Selectors, the | |
|
| LCD will display the following two alternating messages: |
|
| 1. “RAID level” |
|
| “Unmatched” |
|
| 2. “Current: Rx” (i.e. the current RAID level settings of the installed disks) |
|
| “Original: Rx” (i.e. the RAID level settings on the RAID Level Switch Selectors) |
|
| Example: |
|
| The RAID Level Switch Selectors are positioned to indicate a RAID 0 setting, but the disks were set |
|
| earlier as a RAID 5 array, the LCD will display the following two alternating messages: |
|
| 1. “RAID Level” |
|
| “Unmatched” |
|
| 2. “Current: R5” |
|
| “Original: R0” |
|
| In this situation, the array will not function. There are two options: |
|
| 1. Shut down the LaCie Biggest Quadra and |
|
| previous RAID setting, in this case, RAID 5. |
|
| 2. |
|
| it will be lost during the initialization. |
|
|
|