PDG-2515/2520 Operating Manual

 

 

 

 

 

 

Troubleshooting Guide

 

 

No power LED or screen

Check power source, power switch (located on rear

 

 

does not come up.

of unit).

 

 

Pulse exhibits excessive

Check load impedance.

 

 

ringing.

 

 

 

Frequency limits.

Check duty cycle of EACH channel, both channels

 

 

 

must be within the specifications of the unit to

 

 

 

increase the frequency. Note that duty cycle of a

 

 

 

channel is the addition of the pulse width and the

 

 

 

delay.

 

 

Pulse Width limits.

Check the frequency and duty cycle. Note that duty

 

 

 

cycle of a channel is the addition of the pulse width

 

 

 

and the delay settings.

 

 

Pulse Delay limits.

Check the frequency and duty cycle. Note that duty

 

 

 

cycle of a channel is the addition of the pulse width

 

 

 

and the delay settings.

 

 

In external trigger pulse is

Check duty cycle of input trigger signal, check that

 

 

not stable or consistent

the signal frequency and trigger signal duty cycle are

 

 

with settings.

within specification.

 

 

In Burst Mode pulse is

Check to make sure timing constraints are not

 

 

not stable or consistent

exceeded; duty cycle of frequency is not exceeded

 

 

with settings.

with the addition of extra pulses.

 

 

Configuration will not

Make sure a valid configuration had been previously

 

 

load.

saved in configuration slot.

 

 

Sync output not a square

Check sync lines termination; note that sync does

 

 

wave or has excessive

not have same impedance as output lines.

 

 

ringing.

 

 

Page 35

MNPDG2515-2520R0.doc

© 2004 Directed Energy, Inc.

Page 42