Error Set:
First Byte Decimal Hex Error
# 0 0x00 NO ERROR
# 1-63 0x01-0x3A RESERVED
# 64 0x40 DATA IS OUT OF RANGE
# 65 0x41 FREQUENCY IS DC LIMITED
# 66 0x42 PULSEWIDTH IS FREQUENCY LIMITED
# 67 0x43 DELAY IS FREQUENCY LIMITED
# 68 0x44 INVALID CONFIGURATION
# 69-111 0x45-0x6A RESERVED
# 112 0x70 UNRECOGNIZED WORD
# 113 0x71 BAD STRING FORMAT
# 114 0x72 BAD DATA FORMAT
# 115 0x73 UNRECOGNIZED PARSE ERROR
# 116 0x74 BAD RESOLUTION
# 117-119 0x75-0x77 RESERVED
# 120 0x78 COMMAND NOT AVAILABLE
# 121 0x79 INTERNAL SYSTEM ERROR
# 122-255 0x80-0xFF RESERVED